Gestra LRGS 15-1
Gestra
رقم المنتج: LRGS 15-1
المصنع: Gestra
Confirmed Rating:
☆☆☆☆
☆☆ (2.4)
Rating Count: 5543
يرجى الاتصال بفريق الدعم المباشر لدينا أو ملء نموذج العرض عبر الإنترنت للحصول على معلومات مفصلة عن المنتج Gestra - LRGS 15-1 - Gestra LRGS 15-1 سوف نعود إليك في أقرب وقت ممكن.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for Gestra LRGS 15-1
Description for Gestra LRGS 15-1
Technical Data Service pressure PN25: 25 barg at 224 °C Mechanical connection Screwed ¾Inch, ISO 228-1 Screwed ¾Inch NPT (optional) Materials Screw-in electrode body: 1.4571, X6CrNiMoTi17-12-2 or 1.4404, A 479 316 L (for NPT thread) Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 Electrode rod insulation: PTFE Terminal box: Polycarbonate Measuring length & length of installation 200, 300, 400, 500, 600, 800, 1000 mm Input 1 Input for resistance thermometer, e. g. TRG 5-53, measuring insert Pt 100 Measuring range 100 to 10000 µS/cm at 25 °C or 50 to 5000 ppm at 25 °C Setpoint Adjustable between 100 and 10000 µS/cm or 50 to 5000 ppm MAX limit Adjustable between 100 and 10000 µS/cm or 50 to 5000 ppm Switching hysteresis Controller output: –10 % of the adjusted setpoint MAX limit: –3 % of the adjusted MAX limit Temperature coefficient Tk (if a resistance thermometer Pt 100 is connected) 1.6 – 3.0 % per °C, adjustable in steps of 0.1 Supply voltages 230 V, +10 / –15 %, 50-60 Hz 115 V, +10 / –15 %, 50-60 Hz (optional) Power consumption 5 VA Fuse External slow-blow fuse 63 mA at 230 V External slow-blow fuse 125 mA at 115 V Output 3 Volt-free relay contacts 5 A 230 V AC / 30 V DC cos φ = 1 (IEC 61810) Provide contactor with inference suppressor (RC combination). Contact material: AgNi 0.15 Indicators and adjustors 1 Four-digit, seven-segment indicator, red, for showing the actual value (X) / setpoint (W) and status & malfunction messages 2 Amber LEDs for indicating the actual value (X) / setpoint (W) 1 Red LED for indicating the MAX limit 2 Green LEDs for indicating “Valve OPEN / CLOSED” 4 Pushbuttons for parameter settings Cable entry / Electrical connection Cable glands with integrated cable clamp, 3 x M 16 x 1.5 1 Four-pole screw-type terminal strip for mains connection 1 Three-pole screw-type terminal strip for connecting the continuous blowdown valve 1 Three-pole screw-type terminal strip for MAX limit The terminal strips can be detached; conductor size 1.5 mm2 4 Terminal lugs for connecting the resistance thermometer Protection IP 65 to DIN EN 60529 Protection class 2 (protective insulation) Weight Approx. 1.5 kg Ambient temperature when system is switched on: 0 ° ... 70 °C, during operation: -10 ... 70 °C Transport temperature –20 ... +80 °C (< 100 hours), defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Storage temperature –20 ... +70 °C, defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Relative humidity max. 95%, no moisture condensation Site altitude max. 2000 m
Latest Comments for Gestra LRGS 15-1
غيرها من المنتجات الموصى بها Gestra