industrialmaterialcenter.com

Greisinger GT10-CO2-1R CO2 (Carbon Dioxide) Transmitter

Greisinger

رقم المنتج: GT10-CO2-1R
Artikelnummer: 602599
المصنع: Greisinger
Confirmed Rating: ☆☆☆☆ ☆☆ (2.8)
Rating Count: 1140

يرجى الاتصال بفريق الدعم المباشر لدينا أو ملء نموذج العرض عبر الإنترنت للحصول على معلومات مفصلة عن المنتج Greisinger - GT10-CO2-1R - Greisinger GT10-CO2-1R CO2 (Carbon Dioxide) Transmitter سوف نعود إليك في أقرب وقت ممكن.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Greisinger GT10-CO2-1R CO2 (Carbon Dioxide) Transmitter

Description for Greisinger GT10-CO2-1R CO2 (Carbon Dioxide) Transmitter

Due to the fact that CO2 is an important indicator for the quality of air in rooms, it's superimportant to measure the CO2 content. The recommended CO2 limit value for ambient air is 1000ppm. An exceeding of this limit causes tiredness and a loss of concentration.For measuring the CO2 concentration, GREISINGER electronics presents a high quality and precise CO2 transmitter, working according to the infrared principle (NDIR). An auto-calibration procedure compensates aging effects and is responsible for an excellent long term stability of this CO2 transducer. Due to the freely adjustable output signal (4-20mA, 0-1V. 0-10V etc.), the transmitter could be used for nearly each existing controller input etc. Additionally, there is a local display which shows beside the actual CO2 concentration, the minimum and maximum values ​​as well as an optical alarm. If required, the CO2 transmitter could be calibrated via buttons.Highlights:excellent long term stabilityauto-calibration procedurefor surveillance of the recommended CO2 concentration in ambient airlocal displayoutput signal freely adjustablezero point and scale inputvisual alarm displayTechnical details:Measuring Range: 0 ... 2000 ppm CO2Accuracy: ± 50 ppm ± 2% of reading (at 20 ° C, 1013mbar) Output signal: 4-20mA (optional 0-1V, 0-10V etc.), freely adjustableConnection Type: 4-20 mA (3-wire system)Power Supply: Uv = 12 - 30 V DC, Max. 500mA calibration : zero and scale via button adjustabledisplay: approx. 10 mm high, 4-digit LCD displayHousing: ABS (IP65)Dimensions: 82 x 80 x 55 mm (without angle plug)Features: minimum / maximum value memory, optical alarm                                          input of zero and scaleIncluded in Delivery: C02 transmitter, operating manual

Latest Comments for Greisinger GT10-CO2-1R CO2 (Carbon Dioxide) Transmitter


غيرها من المنتجات الموصى بها Greisinger


Greisinger GMH 3161-12 Measuring Instrument
Greisinger GTD1100 Barometer
Greisinger GPB3300 Barometer
Greisinger GPH114 Digital pH-Meter
Greisinger GMH 1170 Precision Quick Response Thermometer
Greisinger GPT 180 Display Module
Greisinger GTH1170 Thermometer
Greisinger GMH3181-01 Pressure Hand-Held Measuring Device
Greisinger GTH175 PT-K Thermometer
Greisinger GMH3181-13 Pressure Hand-Held Measuring Device
Greisinger GOEL370 Oxygen Sensor
Greisinger GDH200-07 Digital Manometer
Greisinger GDH200-13 Digital Manometer
Greisinger GMH3151 Hand-held Pressure Measuring Device
Greisinger GMH3181-07H Pressure Hand-Held Measuring Device
Greisinger GMH 3750 PT100 High Precision Thermometer
Greisinger GMH3161-13 Differential Pressure Unit
Greisinger GOX100-T-LACK Air Oxygen Meter Device