Meggitt Vibro-Meter GSI127 Galvanic Separation Unit
Meggitt
رقم المنتج: Vibro-Meter GSI127
المصنع: Meggitt
Confirmed Rating:
☆☆☆☆☆☆
(4.9)
Rating Count: 3442
يرجى الاتصال بفريق الدعم المباشر لدينا أو ملء نموذج العرض عبر الإنترنت للحصول على معلومات مفصلة عن المنتج Meggitt - Vibro-Meter GSI127 - Meggitt Vibro-Meter GSI127 Galvanic Separation Unit سوف نعود إليك في أقرب وقت ممكن.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for Meggitt Vibro-Meter GSI127 Galvanic Separation Unit
Description for Meggitt Vibro-Meter GSI127 Galvanic Separation Unit
Galvanic separation unit for use with vibration sensor (CA, CE, PV and VE), dynamic pressure sensor (CP) or proximity sensor (TQ) measurement chains.The GSI127 galvanic separation unit is a high-quality, high-reliability unit for use with the IPC704 signal conditioner (used by CA accelerometers and CP dynamic pressure sensors), current-output accelerometers such as the CE134, CE281 and CE311, constant-current voltage-output sensors such as the CE110I, PV102 and CE680Mx11, the IQS450 signal conditioner (used by TQ proximity sensors) or the VE210 velocity sensor.The GSI127 has a configurable transfer function and provides a voltage output. It is designed and built for long-term use in environments characterised by hazardous areas (potentially explosive atmospheres).FeaturesPower supply and galvanic separation unit for sensors and signal conditioners with a current output or a voltage output4 kVRMS galvanic separation between the sensor side and the monitor side50 VRMS galvanic separation between the power supply and the output signal (floating output)μA to mV transfer function for long distance current-signal transmission, V to V transfer function for short-distance voltage-signal transmissionCertified for use in potentially explosive atmospheres PARAMETER VALUE (IMPERIAL | METRIC) Output type Voltage (2-wire) Measurement system CA vibration, CP dynamic pressure, TQ proximity or VE velocity Sensor or signal conditioner IPC704 signal conditioner (CA and CP sensors), CE sensors with a current output, IQS450 signal conditioner (TQ sensors) and VE210 sensor Input signal range (sensor side) 0 to 20 mA or 0 to 20 VDC Output signal range (monitor side) 2 to 20 VDC Transfer function (sensitivity) 1 V/mA ±1%, 3.2 V/mA ±1%, 1 V/V ± % or −1 V/V ±1% Transfer function (output offset voltage) 7 VDC ±0.2 VDC, 8 VDC ±0.2 VDC or 10 VDC ±0.2 VDC Frequency range DC to 20000 Hz Linearity <0.2% Galvanic separation 4 kVRMS Operating temperature range 32 to 158 °F | 0 to 70 °C Hazardous area certifications Ex nA [ia Ga], AEx nA [ia Ga]
Latest Comments for Meggitt Vibro-Meter GSI127 Galvanic Separation Unit
غيرها من المنتجات الموصى بها Meggitt