MOELLER XPOLE PL7 B25/1 Miniature circuit breaker

MOELLER XPOLE PL7 B25/1 Miniature circuit breaker. MOELLER, XPOLE, MOELLER XPOLE, PL7, MOELLER PL7, XPOLE PL7, MOELLER XPOLE PL7, B25/1
يمكنك الحصول على عرض الآن: info@industrialmaterialcenter.com
رقم المنتج XPOLE PL7 B25/1
المصنع MOELLER
Artikelnummer 262678

Description: XPOLE PL7 B25/1 ( MOELLER )

MOELLER XPOLE PL7 B25/1 Miniature circuit breaker



Product Name: MOELLER XPOLE PL7 B25/1 Miniature circuit breaker
Product Brand: MOELLER
Product Code: XPOLE PL7 B25/1
Product Artikel: 262678
TECHNICAL DATA Electrical Rated switching capacity according to IEC/EN 60898-1 [I cn ] 10 kA DESIGN VERIFICATION AS PER IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation [I n ] 25 A Heat dissipation per pole, current-dependent [P vid ] 0 W Equipment heat dissipation, current-dependent [P vid ] 3 W Static heat dissipation, non-current-dependent [P vs ] 0 W Heat dissipation capacity [P diss ] 0 W Operating ambient temperature min. -25 °C Operating ambient temperature max. +75 °C linear, per +1 °C, results in a 0.5% reduction of current carrying capacity IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2 Strength of materials and parts 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2 Strength of materials and parts 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9 Insulation properties 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9 Insulation properties 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TECHNICAL DATA ETIM 7.0 Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss10.0.1-27-14-19-01 [AAB905014]) Release characteristic B Number of poles (total) 1 Number of protected poles 1 Rated current 25 A Rated voltage 230 V Rated insulation voltage Ui 440 V Rated impulse withstand voltage Uimp 4 kV Rated short-circuit breaking capacity Icn EN 60898 at 230 V 10 kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V 10 kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 0 kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 0 kA Voltage type AC Frequency 50 - 60 Hz Current limiting class 3 Suitable for flush-mounted installation No Concurrently switching N-neutral No Over voltage category 3 Pollution degree 2 Additional equipment possible Yes Width in number of modular spacings 1 Built-in depth 70.5 mm Degree of protection (IP) IP20 Ambient temperature during operating -25 - 55 °C Connectable conductor cross section multi-wired 1 - 25 mm² Connectable conductor cross section solid-core 1 - 25 m m²

غيرها من المنتجات الموصى بها MOELLER