PHOENIX CONTACT 2761622 SUBCON 25/M-SH D-SUB bus connector

PHOENIX CONTACT 2761622 SUBCON 25/M-SH D-SUB bus connector. PHOENIX, CONTACT, PHOENIX CONTACT, 2761622, PHOENIX 2761622, CONTACT 2761622
يمكنك الحصول على عرض الآن: info@industrialmaterialcenter.com
رقم المنتج 2761622 SUBCON 25/M-SH
المصنع PHOENIX CONTACT

Description: 2761622 SUBCON 25/M-SH ( PHOENIX CONTACT )

PHOENIX CONTACT 2761622 SUBCON 25/M-SH D-SUB bus connector



Product Name: PHOENIX CONTACT 2761622 SUBCON 25/M-SH D-SUB bus connector
Product Brand: PHOENIX CONTACT
Product Code: 2761622 SUBCON 25/M-SH
Product Artikel: PHOENIX CONTACT 2761622 SUBCON 25/M-SH D-SUB bus connector
Dimensions Max. cable diameter 10 mm Min. cable diameter 4 mm Width 16 mm Height 55 mm Length 79 mm Back to top Environmental conditions Ambient temperature (operation) -20 ° C ... 75 ° C Ambient temperature (stock / transport) -25 ° C ... 80 ° C Altitude ≤ 5000 m (For limitations, see manufacturer's declaration for operation by altitude above sea level) Protection class IP20 IP20 Back to top General Nominal voltage UN 50 V DC Nominal current IN 100 mA Modbus signal RS-232 RS-422 RS-485 Insertion / pull cycles> 200 SUBCON set screws 4-40 UNC Tightening torque 0.4 Nm Housing material ABS, metal coated Pin assignment All connections are 1: 1 on the screw terminal block MTTF 6706 Years (SN 29500 standard, temperature 25 ° C, working cycle 21% (5 days a week, 8 hours a day)) 1817 Years (SN 29500 standard, temperature 40 ° C, working cycle 34.25% (5 days a week, 12 hours a day)) 155 Years (SN 29500 standard, temperature 40 ° C, working cycle 100% (7 days a week, 24 hours a day)) Back to top Connection data Connection D-SUB connection No. of poles 25 Connection method D-SUB connector Connection PCB connection Connection method Screw connection Multi vein min. conductor cross section area 0,14 mm² Multicore max. conductor cross section area 1 mm² Single core min. conductor cross section area 0,14 mm² Single core max. conductor cross section 1.5 mm² Min. AWG conductor cross section, stranded 26 Max. AWG conductor cross section, stranded 18 Conductor cross section AWG min. 26 Conductor cross section AWG max. 16 Cable stripping length 5 mm Tightening torque 0.4 Nm Back to top Conformity / approvals EAC definition identification EAC Description ATEX Description  II 3 G Ex nA IIC T4 Gc X Additional text Please pay attention to the special assembly instructions given in the document! Description Corrosive gas test Description ISA-S71.04-1985 G3 Harsh Group A

غيرها من المنتجات الموصى بها PHOENIX CONTACT