SICK 6044739 type: WL280-2H1531 Retro-reflective Sensor

SICK 6044739 type: WL280-2H1531 Retro-reflective Sensor. SICK, 6044739, SICK 6044739, type:, SICK type:, 6044739 type:, SICK 6044739 type:
يمكنك الحصول على عرض الآن: info@industrialmaterialcenter.com
رقم المنتج WL280-2H1531
المصنع SICK

Description: WL280-2H1531 ( SICK )

SICK 6044739 type: WL280-2H1531 Retro-reflective Sensor



Product Name: SICK 6044739 type: WL280-2H1531 Retro-reflective Sensor
Product Brand: SICK
Product Code: WL280-2H1531
Product Artikel: SICK 6044739 type: WL280-2H1531 Retro-reflective Sensor
FEATURES Sensor/ detection principle Photoelectric retro-reflective sensor, Dual lens Dimensions (W x H x D) 23.5 mm x 74.5 mm x 63 mm Housing design (light emission) Rectangular Sensing range max. 0.01 m ... 15 m  1) Sensing range 0.01 m ... 13 m  1) 0.01 m ... 11 m  2) Type of light Visible red light Light source LED  3) Light spot size (distance) Ø 260 mm (8 m) Adjustment Potentiometer 1)  Reflector PL80A. 2)  Reflector P250. 3)  Average service life: 100,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 24 V DC ... 240 V DC  1) 24 V AC ... 240 V AC  1) Power consumption ≤ 5 VA Switching output Relay, electrically isolated  2) Output function Change-over contacts Switching mode Light switching  2) Switching current (switching voltage) 3 A (240 V AC) 3 A (30 V DC) Response time ≤ 15 ms Switching frequency 33 Hz  3) Connection type Cable, 5-wire, 2 m  4) Cable material PVC Conductor cross-section 0.76 mm² Circuit protection A  5) C  6) Protection class II  7) Overvoltage category 2 Weight 150 g Polarisation filter ✔ Interference emission EN 61000-6-3 (only –2Hxxxx)  8) Housing material Plastic, ABS Optics material Plastic, PMMA Enclosure rating IP66 IP67 Items supplied Mounting bracket BEF-W280, Reflector P250 Usage category AC-15, DC-13, according to EN 60947-1 EMC EN 60947-5-2  9) Ambient operating temperature –25 °C ... +55 °C Ambient storage temperature –40 °C ... +70 °C 1)  ±10 %. 2)  Provide suitable spark suppression for inductive or capacitive loads. 3)  With light/dark ratio 1:1. 4)  Do not bend below 0 °C. 5)  A = V S  connections reverse-polarity protected. 6)  C = interference suppression. 7)  Rated voltage: 250 V AC/DC. 8)  In the case of a DC supply (relating to EN 61000-6-3) the length of cable between the supply source and the sensor must be 9)  The AC/DC devices (-2Rxxxx only) comply with the Radio Safety Requirements for the industrial sector (Radio Safety Class A). They may cause radio interference if used in a residential area. SAFETY-RELATED PARAMETERS MTTF D 1,537 years DC avg 0% CLASSIFICATIONS ECl@ss 5.0 27270902 ECl@ss 5.1.4 27270902 ECl@ss 6.0 27270902 ECl@ss 6.2 27270902 ECl@ss 7.0 27270902 ECl@ss 8.0 27270902 ECl@ss 8.1 27270902 ECl@ss 9.0 27270902 ECl@ss 10.0 27270902 ECl@ss 11.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 UNSPSC 16.0901 39121528

غيرها من المنتجات الموصى بها SICK