Barksdale Series 433, 435, 436 Non-Incendive Transducer
Barksdale
Produktnummer: Series 433, 435, 436
Hersteller: Barksdale
Confirmed Rating:
☆☆☆☆☆
☆ (3.7)
Rating Count: 10041
Wenden Sie sich an unser Live-Support-Team, um weitere Informationen zum Barksdale Series 433, 435, 436 Non-Incendive Transducer-Markencode von Barksdale zu erhalten, oder füllen Sie ein Online-Angebotsformular aus. Wir werden uns so schnell wie möglich bei Ihnen melden.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for Barksdale Series 433, 435, 436 Non-Incendive Transducer
Description for Barksdale Series 433, 435, 436 Non-Incendive Transducer
Barksdale's 430 Series Non-IncendiveTransducers prevent an explosion from occurring when operated in a Division II environment. Barksdale's 430 Series, non-incendive transducers prevent personal injury and machinery damage by preventing the explosion in the first place. Energy generated within the transducer is of such a low level that intermittently present flammable vapors will not be ignited. External zener barriers are not required in order to meet UL requirements for a non-incendive installation. Three models are available: Series 433 (0-5V), Series 435 (4-20mA) and Series 436 (0-10V).General Specifications*Accuracy (LH & R):±0.25% FSO at 75°F (±0.5% for vacuum only [-23]) typicalLong Term Stability:±0.5% FSO of calibration curveTypical Life Cycle:100 million cyclesProof Pressure:2 times rated pressure or 13,000 psi max. (884 bar), whichever is lessInput:433:436:435:Excitation voltage: 11 to 30 VDCExcitation voltage: 14 to 30 VDCExcitation voltage: 12 to 28 VDCSupply Current:3.0 mA maximum (no load)Min. Load Resistance:2K ohms (voltage series)Output:433:436:435:Output: 0.5 to 5.5 VDCFull scale output: 5.0 VDC ± 0.8%Zero output: 0.5 VDC ± 0.4%Output: 1 to 11 VDCFull scale output: 10 VDC ± 0.4%Zero output: 1.0 VDC ± 0.2%Output: 4 to 20 mAFull scale output: 16 mA ± 1%Zero output: 4 mA ± 2%Wetted Parts:17-4 PH (fitting) & 300 stainless steel (sensor)Enclosure:NEMA 4, 300 series stainless steelPressure Connection:1/4”-18 NPT maleResponse Time:2kHzElectrical Connection:3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground (standard).Temperature Ranges:Operating:Compensated:Storage:-40° to 158°F (-40° to 70°C)-40° to 158°F (-40° to 70°C)-40° to 185°F (-40° to 85°C)Temperature Shift:Zero & Span:0.01% per °F over compensated rangeVibration:15 g’s, 10-2000 Hz, MIL-STD 202Shock:50 g’s, 11 ms, MIL-STD 202 Method 213, Cond. G.Approvals:Nonincendive pressure transmitters are UL and cUL approved as telemetering equipment for use in Div. 2 hazardous locations as follows:Class I, Div. 2, Groups A, B, C & DClass II, Div. 2 Groups F & GAgency approval varies by electrical termination type as follows:H5(-E) models are cULus listed in UL File E146589, (WYMV, WYMV7).H3(-E), T4(-E) & T5 (-E) models are cURus recognized components in UL File E146589, (WYMV2, WYMV8).Weight:433 & 436:435:7.4 oz. (221 grams) to 1,000 psi9.9 oz. (281 grams) 2,000 psi and higher7.4 oz. (210 grams) to 1,000 psi9.4 oz. (266 grams) 2,000 psi and higherWarranty:1 year warranty* See product confi gurator for additional options.Wiring CodeMILLIVOLT SERIES - 433 & 436(T4/T5)(H3/H5)Signal1Red+ Excitation3White+ Output2BlackCommon4BareDrainMILLIAMP SERIES - 4351Red+ Excitation2Black- Excitation4BareCase Drain
Latest Comments for Barksdale Series 433, 435, 436 Non-Incendive Transducer
Produktvorschläge Barksdale