Barksdale Series 450 Intelligent Transmitter

Bitte kontaktieren Sie unser Live-Support-Team für weitere Informationen zu Barksdale Series 450 Intelligent Transmitter. Barksdale, Series, Barksdale Series, 450, Barksdale 450, Series 450, Barksdale Series 450
Produkte die mit A beginnen: info@industrialmaterialcenter.com
Produktnummer Series 450
Hersteller Barksdale

Description: Series 450 ( Barksdale )

Barksdale Series 450 Intelligent Transmitter



Product Name: Barksdale Series 450 Intelligent Transmitter
Product Brand: Barksdale
Product Code: Series 450
Product Artikel: Barksdale Series 450 Intelligent Transmitter
Barksdale Intelligent Transmitters (BiT), Series 450 is a high pressure transmitter with HART® communication protocol option. HART® enabled sensors can communicate over the legacy two-wire 4-20 mA analog current loops offering smart features like transmitter diagnostics, calibration, and field re-ranging up to 10 times less than calibrated full scale output (10:1 turndown ratio). Three models are available: Series H455, 4-20 mA output with HART® Comm. Protocol; Series 455, 4-20 mA output; Series 452, 1-5 VDC output. These models can be configured with 24-standard pressure ranges from vacuum to 30,000 psi and multiple process connections from 1/4” NPT to 7/16” SAE and HF4 Autoclave high-pressure connections. Multiple electrical connections are also offered, including popular industrial and MS style connectors for easy connection. Series 450 offers cULus approval for ordinary location. General Specifications* Accuracy including Linearity, Hysteresis and Repeatability: at 75°F, Typical ±0.1% of Calibrated FSO (Option [–A1]) ±0.25% of Calibrated FSO (Standard) ±0.5% of Calibrated FSO (Vacuum only [-23]) Temperature Shift: Zero & Span: 0.0125% Per °F over the compensated temperature range Long Term Stability:closure rating: ±0.2% FSO /year of calibration curve Typical Life Cycle: 100 million cycles Proof Pressure: 2X range for up to 7500 psi models 1.5X range for 7500 - 30000 psi models Input: H455: 455*: 452*: Excitation voltage: 9 to 30 VDC Excitation voltage: 9 to 30 VDC Excitation voltage: 12 to 30 VDC * (SELV, PELV), Class II Power Supply Supply Current: H455 & 455: 452: 20mA max. 20mA max. Output: H455: 455: 452: Output: 4–20 mA with HART® Protocol Full Scale Output: 20 mA ±1% Zero output: 4 mA ±1% Output: 4–20 mA Full Scale Output: 20 mA ±1% Zero output: 4 mA ± 1% Output: 1–5 VDC Full scale output: 5.0 VDC ± 1% Zero output: 1.0 VDC ± 1% Dynamic Response Time: H455: 455 & 452: <70 milliseconds <50 milliseconds Enclosure: All welded 300 series stainless steel. IP66 & IP67 and NEMA 4X rated. 316 Stainless Steel (optional) Wetted Parts: Sensor: Fitting: 17-4 PH Stainless steel (more than 10k psi) 316L Stainless steel (up to 10k psi) Inconel (optional: up to 10k psi) 17-4 PH Stainless Steel for -UL option (10k psi) 17-4 PH Stainless steel (all ranges) 316L Stainless steel and 718 Inconel (optional: up to 10k psi) Media General: Corrosive and Acidic: (up to 10,000 psi) Gas, vapor, liquid and viscous fluids [-Z17] 718 Inconel wetted material, NACE [-NC]; and 316L Stainless Steel, NACE [-SS] Pressure Connection: 13 available options. Refer to product configurator for available connections and ranges. Electrical Connection: 3 conductors for voltage output series and 2 conductors for current output series, 18 AWG, 80” (2 m) long with integral strain relief and case ground (standard). Jacketed cable (optional). Halogen free wires and cable. Temperature Ranges: Operating (Ambient): Compensated: Media: Storage: -40 to +176 °F (-40 to +80 °C) 0 to +165 °F (-18 to +74 °C) -40 to +176 °F (-40 to +80 °C) -40 to +185 °F (-40 to +85 °C) Vibration: 10 g’s, 10-500 Hz, MIL-STD 202, Method 204, Cond. A Shock: 50 g’s, 11 mS, MIL-STD 202 Method 213, Cond. G. Approvals: cULus: cULus approved for ordinary locations (UL 61010-1) HART® Protocol: Turndown Ratio: Analog Output Calibration: Sensor Trim: Diagnostics: HART® 7.6 10:1 (Full scale output rangeability) Adjustable zero and span of 4-20mA. Full scale range must be ≥ (calibrated span / 10) Sensor zero and full scale trim Transmitter failure indicated by off-scale analog signals to alarm the user See HART Installation and Operation Manual 272438 for detailed information Compliances: CE, CRN (refer to drawing # 272479 for applicable models) NACE (316L SS or 718 Inconel wetted material) Electromagnetic Compatibility (EMC) IEC/EN 55011: IEC/EN 61000-4-2: IEC/EN 61000-4-3: IEC/EN 61000-4-4: H455: 455 & 452: IEC/EN 61000-4-5: H455: 455 & 452: IEC/EN 61000-4-6: Emission & radiated emission for class A limits Electrostatic discharge (ESD) test - contact discharge +/-4 kV, Air discharge +/-8 kV Radiated RF, EM field immunity 80mhz-1ghz, 3v/M EFT (Burst) Test, +/-2 kV EFT (Burst) Test, +/-1 kV Surge Test, +/-1kV between line and earth ground Surge test not applicable; Class II power supply used at input of the device RF Immunity, 150 kHz – 80 MHz, 3V Weight: 16 Ounces (453 grams) Warranty: 1 year warranty

Produktvorschläge Barksdale