BECKHOFF EL3255 HD Ethercat Terminal

Bitte kontaktieren Sie unser Live-Support-Team für weitere Informationen zu BECKHOFF EL3255 HD Ethercat Terminal. BECKHOFF, EL3255, BECKHOFF EL3255, , BECKHOFF , EL3255 , BECKHOFF EL3255 , HD, BECKHOFF HD, EL3255 HD
Produkte die mit A beginnen: info@industrialmaterialcenter.com
Produktnummer EL3255
Hersteller BECKHOFF

Description: EL3255 ( BECKHOFF )

BECKHOFF EL3255 HD Ethercat Terminal



Product Name: BECKHOFF EL3255 HD Ethercat Terminal
Product Brand: BECKHOFF
Product Code: EL3255
Product Artikel: BECKHOFF EL3255 HD Ethercat Terminal
The EL3255 EtherCAT Terminal enables potentiometers to be connected directly. A stabilised power supply in the terminal and the ratiometric measurement of the input voltage offer the preconditions for precise measurement. On account of its high sampling rate and together with potentiometer position encoders, the compact 5-channel EtherCAT terminal represents an economical position detector. The HD EtherCAT Terminals (High Density) with increased packing density feature 16 connection points in the housing of a 12 mm terminal block. Technical data EL3255 Number of inputs 5 Power supply via power contacts Technology ratiometric potentiometer evaluation with supply, 3-wire Distributed clocks yes Feed voltage potentiometer typ. 10 V ±10 % Internal resistance >> 100 kΩ to wiper connection Input filter limit frequency typ. -3 dB at 3 kHz and potentiometer 50 kΩ Sensor types potentiometer 300 Ω…50 kΩ Output current max. 0.3 A total supply current for the potentiometers Wiring fail indication yes Conversion time typ. 300…700 µs, dependent on settings, default setting: approx. 500 µs (5 channels, filter deactivated) Measuring range potentiometer 300 Ω…50 kΩ Resolution 16 bit (incl. sign) Measuring error < ±0.5 % (relative to full scale value) Electrical isolation 500 V (E-bus/field potential) Current consumption power contacts dependent on the potentiometers, max. 70 mA Current consumption E-bus typ. 80 mA Bit width in the process image 5 x 16 bit input Configuration no address setting, configuration via the controller Conductor types solid wire, stranded wire and ferrule Conductor connection solid wire conductors: direct plug-in technique; stranded wire conductors and ferrules: spring actuation by screwdriver Rated cross-section solid wire: 0.08…1.5 mm²; stranded wire: 0.25…1.5 mm²; ferrule: 0.14…0.75 mm² Special features open-circuit recognition, supply monitoring, activatable filters, simultaneous measurement of the channels Weight approx. 70 g Operating/storage temperature -25…+60 °C/-40…+85 °C Relative humidity 95 %, no condensation Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27 EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4 Protect. class/installation pos. IP 20/variable

Produktvorschläge BECKHOFF