industrialmaterialcenter.com

Gestra TRS5-40

Gestra

Produktnummer: TRS5-40
Hersteller: Gestra
Confirmed Rating: ☆☆☆☆☆☆ (4.1)
Rating Count: 14966

Wenden Sie sich an unser Live-Support-Team, um weitere Informationen zum Gestra TRS5-40-Markencode von Gestra zu erhalten, oder füllen Sie ein Online-Angebotsformular aus. Wir werden uns so schnell wie möglich bei Ihnen melden.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Gestra TRS5-40

Description for Gestra TRS5-40

DescriptionThe control unit TRS 5-40 together with the temperature sensors TRS 5-6x and the temperature transmitter TRV 5-40 constitutes a temperature monitoring system. Two temperature sensors TRG 5-6x detect the temperature values which are then converted by the temperature transmitter TRV 5-40 and made available for the CAN bus in the form of a data telegram. The CANopen protocol is used for the data transfer via CAN bus. The control unit TRS 5-40 can be used ■ as MIN and MAX temperature monitor in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x each and ■ as temperature controller in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x (MIN or MAX) The control unit TRS 5-40 is also available with two actual value outputs 4 - 20 mA. The equipment combinations can be used for controlling or monitoring temperatures in steam boilers and (pressurised) hot water installations to TRD and EN 12952 and EN 12953.Function The control unit TRS 5-40 evaluates the data telegram coming from the temperature transmitter TRV 5-40 at regular intervals. This data telegram contains: ■ Actual value and ajdusted switchpoint for measuring channel 1, ■ Actual value and ajdusted switchpoint for measuring channel 2, ■ Temperature in the housing of the temperature transmitter. In addition, the following error messages are also included in the data telegram: ■ Malfunction in the temperature sensor (sensor damaged, short circuit), ■ Temperature in the housing of the temperature transmitter too high, ■ Communication error. The output relays 1 – 4 are assigned to the measuring channels 1 and 2 as follows: ■ Measuring channel 1: Output relay 1 ■ Measuring channel 2: Output relays 2, 3 and 4. To activate or de-activate the measuring channels and to set the functions use the code switch or the operating & display unit URB 2. Use the operating & display unit URB 2 to set the MIN / MAX temperature switchpoints for the temperature control as well as to establish the actual value outputs. If there is an error message relay(s) 1 and/or 4 will be de-energized.

Latest Comments for Gestra TRS5-40


Produktvorschläge Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART