Bitte kontaktieren Sie unser Live-Support-Team für weitere Informationen zu Mts Sensor 551993 Liquid Level Transmitters. Mts, Sensor, Mts Sensor, 551993, Mts 551993, Sensor 551993, Mts Sensor 551993, , Mts
Produkte die mit A beginnen: info@industrialmaterialcenter.com
Produktnummer 551993
Hersteller Mts Sensor

Description: 551993 ( Mts Sensor )

Mts Sensor 551993 Liquid Level Transmitters



Product Name: Mts Sensor 551993 Liquid Level Transmitters
Product Brand: Mts Sensor
Product Code: 551993
Product Artikel: Mts Sensor 551993 Liquid Level Transmitters
Level Output Measured Variable Product level and interface level Output Signal /Protocol Modbus RTU Order Length Flexible hose: 1575...22000 mm (62...866 in.) Rigid pipe: 305...7620 mm (12...300 in.) Inherent Accuracy ±1 mm (0.039 in.) Repeatability 0.001% F.S. or 0.381 mm (0.015 in.) whichever is greater (any direction) Temperature Output Measured Variable Average and multipoint temperatures Temperature Accuracy ±0.2 °C (0.4 °F) range −40…−20 °C (−40…−4 °F), ±0.1 °C (0.2 °F) range −20…+70 °C (−4…+158 °F), ±0.15 °C (0.3 °F) range +70…+100 °C (+158…+212 °F), ±0.5 °C (0.9 °F) range +100…+105 °C (+ 212 …221 °F) Digital I/O Input Voltage Up to 30 VDC Resistance 500 Ohm Current Switch Capability 50 mA @ 28 VDC Compatibility ABB RMC 100, Emerson ROC 827, Xetawave I/O, and others Cable Cat5 or equivalent type cable is required (15pF/ft. or 49pF/m) for a max run of 4000 ft. (1200 m) Electronics Input Voltage 10.5…28 VDC Fail Safe High, Full scale Reverse Polarity Protection Series diode EMC EN 61326-1, EN 61326-2-3, EN 61326-3-2, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 61000- 4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 Environmental Enclosure Rating NEMA Type 4X, IP65 Humidity 0…100% relative humidity, non-condensing Operating Temperatures Electronics: −40…+71 °C (−40…+160 ºF) Sensing element: −40…+125 °C (−40…+257 °F) (contact factory for specific temperature ranges) Temperature element: −40…+105 °C (−40…+221 °F) Vessel Pressure Flexible Hose: 30 bar (435 psi) Rigid Pipe: 69 bar (1000 psi) Materials Wetted parts: 316L stainless steel (contact factory for alternative materials) Non-wetted parts: 316L stainless steel, Epoxy coated aluminum Field Installation Housing Dimensions Dual cavity: 117 mm (4.6 in.) W × by 127 mm (5 in.) D × 206 mm (8.1 in.) H Mounting Flexible hose or Rigid pipe 4 in. adjustable MNPT Wiring Connections Terminal block Electrical connections Dual cavity ¾ in. FNPT conduit opening, M20 for ATEX/IECEx version Display Measured variables Product level, interface level and temperature

Produktvorschläge Mts Sensor