industrialmaterialcenter.com

Tecsis EZE15X002 Strain Gauge Measurement Amplifier

Tecsis

Número de producto: EZE15X002
Productor: Tecsis
Confirmed Rating: ☆☆☆☆ ☆☆ (2.5)
Rating Count: 10718

Puede rellenar el formulario de presupuesto en línea o ponerse en contacto con el equipo de asistencia en directo para obtener el Tecsis marca, EZE15X002 producto. Nos pondremos en contacto con usted lo antes posible.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Tecsis EZE15X002 Strain Gauge Measurement Amplifier

Description for Tecsis EZE15X002 Strain Gauge Measurement Amplifier

Strain gauge amplifiers are used to transform the mV/V output-signals of strain gauges in amplified signals with a higher fault resistance. By the use of an amplifier it is also possible to connect sensors to displays and controlling units with the need for an amplified signal. The model EZE15X002 is cased in a space saving slim plastic housing, which allows to use it for top hat rail mounting according to DIN EN 50 022. Interfering signals can be damped by a low-pass filter.FeaturesStrain gauge amplifier for top hat rail mountingOutputsignals 0/4...20mA or 0...±10 V or 0...±5 V (3-Wire) Accuracy 0,02% of full scale Limit frequency up to 1kHz (-3db) for dynamic applications Also available with 5 KHz (-3db) or 10 kHz (-3db) (optional) Needed power supply 10-30 VDC Can be used with load cells with 100% Control-shuntSpace-saving design of the housing Zero point, span and filter adjustable Protection Class IP 20ApplicationIn combination with force transducers or load cells the strain gauge amplifier EZE15X002 can be used in applications to measure forces or in industrial weighing. It is possible to connect all kinds of strain gauges with an output signal between 0.3 mV/V and 3.5 mV/V. The internal sensor supply is 10 VDC or optional 5 VDC. Usually the amplifier is not pre-adjusted and the customer connects it to the force transducer and also adjusts it. Because of the 3-wire analogue output with 4...20 mA; 0...10 V or 0...5 V and the needed supply energy for the amplifier between 10 and 30 V it is possbile to connect the modelEZE15X002 series directly to PLC. Those normaly come with matching analogue inputs which offer a supply energy of 24 V.

Latest Comments for Tecsis EZE15X002 Strain Gauge Measurement Amplifier


Otros productos recomendados Tecsis


Tecsis F1112 Hydraulic Compression Force Transducer
Tecsis F3301 Shear Beam
Tecsis F33C1 Shear Beam
Tecsis F33S1 Shear Beam
Tecsis F3833 Bending Beam
Tecsis F3831 Shear Beam
Tecsis F1222 Compression Force Transducer
Tecsis F1224 Miniature Compression Load Cell From 1 kN
Tecsis F1212 Compression Force Transducer
Tecsis F1226 Compression Force Transducer
Tecsis F1101 Hydraulic Compression Force Transducer
Tecsis F1102 Hydraulic Compression Force Transducer
Tecsis F1103 Hydraulic Compression Force Transducer
Tecsis F1106 Hydraulic Compression Force Transducer
Tecsis F1115 Hydraulic Compression Force Transducer
Tecsis F1119 Hydraulic Compression Force Transducer
Tecsis F1122 Hydraulic Compression Force Transducer
Tecsis F1125 Hydraulic Compression Force Transducer