industrialmaterialcenter.com

Gestra KH Steam-Powered Condensate-Return Unit

Gestra

Numéro de produit: KH
Fabricant: Gestra
Confirmed Rating: ☆☆☆☆☆ (3.4)
Rating Count: 9287

Veuillez contacter notre équipe d'assistance en direct ou remplir le formulaire d'offre en ligne pour obtenir des informations détaillées sur le produit Gestra KH Gestra KH Steam-Powered Condensate-Return Unit Nous reviendrons vers vous dès que possible.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Gestra KH Steam-Powered Condensate-Return Unit

Description for Gestra KH Steam-Powered Condensate-Return Unit

Description The condensate flows into the upright cylindrical tank, displacing the air through a solenoid valve. The tank is equipped with the compact level system type NRGS 11-1 / NRGS 16-1. As soon as the water level reaches the upper electrode tip the solenoid valve in the vent line is closed and simultaneously the solenoid valve in the booster-steam line (introduced from above into the tank) is opened. The flowing steam pushes the condensate via the condensate main into the condensate tank. The condensate level sinks and when the lower electrode tip emerges, the solenoid valve in the booster-steam line is closed and the solenoid valve in the vent line opened. The cycle repeats itself. Before entering the condensate-return unit the condensate is collected in a condensate header to be provided on site. This condensate header should be equipped with a vent. Condensate inlet and outlet are provided with GESTRA DISCO non-return valves type RK. The condensate-return unit is equipped with a pressure-gauge and the booster-steam line with a stop valve with characterized valve cone which permits the adjustment of the booster-steam pressure in accordance with the length of the condensate discharge line and the prevailing back pressure. As the condensate-return unit operates without a float it is unaffected by waterhammer. Continuous drainage of the booster-steam line upstream of the solenoid valve is ensured by a GESTRA steam trap. The steam traps, non-return valves and compact systems are described in separate data sheets.

Latest Comments for Gestra KH Steam-Powered Condensate-Return Unit


Autres produits recommandés Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART