Gestra LRS1-7

Gestra

Numéro de produit: LRS1-7
Fabricant: Gestra
Confirmed Rating: ☆☆☆☆☆ (3.3)
Rating Count: 8163

Veuillez contacter notre équipe d'assistance en direct ou remplir le formulaire d'offre en ligne pour obtenir des informations détaillées sur le produit Gestra LRS1-7 Gestra LRS1-7 Nous reviendrons vers vous dès que possible.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Gestra LRS1-7

Description for Gestra LRS1-7

Description The conductivity switch LRS 1-7 in conjunction with the conductivity electrode LRG 16-9 constitutes a conductivity monitoring and control system. The electrical conductvity of n Condensate, n Boiler feedwater, n Cooling and cleaning water, n Boiler water is monitored. In steam boiler plants the conductivity monitoring & control system is used as limit switch and continuous blowdown controller.Technical Data Type approval TÜV.WÜL.xx-014 Supply voltage 230 V, +10/–15 %, 50-60 Hz 115 V, +10/–15 %, 50-60 Hz (option) Input 1 Input for conductivity electrode LRG 16-9 Output 3 volt-free relay contacts, max. contact rating for switching voltages 115 V AC and 230 V AC: resistive/inductive 4 A. Provide contactor with interference suppressor (RC combination). Contact material: AgNi 0,15. 1 Current output 4-20 mA as actual value output, max. load 500 Ω Measuring range 0.5 to 10000 µS/cm at 25 °C or 0.25 to 5000 ppm at 25 °C.Setpoint adjustable between 0.5 and 9999 μS/cm or 0.25 to 5000 ppm MAX limit adjustable between 0.5 and 9999 μS/cm or 0.25 to 5000 ppm Correction factor adjustable between 0.05 and 5,000, adjustable in increments of 0.001 Temperature coeffizient Tk 0.0 – 3.0 % per °C, adjustable in increments of 0.1 Actual value output 4 mA corresponds to 0.5 μS/cm 20 mA corresponds to 10, 200, 500, 1000, 6000, 9999 μS/cm or 5, 100, 250, 500, 3000, 5000 ppm, final values adjustable Purging interval (continuous blowdown valve is forced to open) adjustable between 1 h and 24 h in increments of 1 h. Duration of purging adjustable between 1 min. and 6 min. in increments of 1 min. Switching hysteresis Controller output: – 10 % of the adjusted setpoint W, Limit MAX: – 3 % of the adjusted MAX limit Indicators and adjustors 1 four-digit, seven-segment indicator, red, for indicating the actual value / setpoint and for status and error messages 2 amber LEDs for indicating actual value (X) / setpoint (W) 1 red LED for indicating MAX limit 2 green LEDs for indicating valve OPEN / CLOSED 4 pushbuttons for value and parameter settings

Latest Comments for Gestra LRS1-7


Autres produits recommandés Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART