industrialmaterialcenter.com

Goyen ISP-ACAC40-PCA Sensor

Goyen

Numéro de produit: ISP-ACAC40-PCA
Fabricant: Goyen
Confirmed Rating: ☆☆☆☆☆ (3.5)
Rating Count: 2032

Veuillez contacter notre équipe d'assistance en direct ou remplir le formulaire d'offre en ligne pour obtenir des informations détaillées sur le produit Goyen ISP-ACAC40-PCA Goyen ISP-ACAC40-PCA Sensor Nous reviendrons vers vous dès que possible.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Goyen ISP-ACAC40-PCA Sensor

Description for Goyen ISP-ACAC40-PCA Sensor

Integrato Sequencer DP AC-IN AC-OUT 40-0/P Polycarbonate Enclosure ATEX with dP sensorThe Integrato Sequencer (IS & ISP) features integrated controls intended for use with larger reverse pulse jet filter cleaning systems. The IS & ISP have been designed to operate across a wide range of environmental conditions. It is suitable for use with all types of filters, including bags, cartridges, sintered metal or ceramic filters. ISP has a built-in differential pressure sensor, allowing this sequencer to be demand drivenFeatures & Specifications:DP SUPPORT : 0 to 4.5 kPaINPUT VOLTAGE AC: 100/240 V @ 50/60 HzOUTPUT VOLTAGE AC: 100/240 V @ 50/60 Hz (same as input), DC: 24 VMAXIMUM INPUT POWER : AC IN, AC OUT Model: 225 W, AC IN, DC OUT Model: 65 WDISCRETE SOLENOID OUTPUTS : 12, 20 or 40 outputsENCLOSURE : Polycarbonate or no enclosurePROTECTION RATING (LARGE ENCLOSURE) : Polycarbonate: IP 66/67 & NEMA 1, 3, 3S, 4, 4X, 6, 6P & 12PROTECTION RATING (SMALL ENCLOSURE) : Polycarbonate: IP65 & NEMA 1, 4, 4X, 12 & 13OPERATING TEMPERATURE : −40°C to 60°C (−40°F to 140°F)ON & OFF TIME ON : 30 ms to 1000 ms, OFF: 1 s to 1000 sINPUTS Voltage Free : Fan Stop, Low Header AlarmOUTPUTS Voltage Free : Coil ErrorAnalogue Output : 4–20 mA dP signal on the ISPLow temperature operation −40°C (−40°F)Automatic valve detection.Voltage-free coil error output and a visual indication on the display showing which pilot valve output has an error, enabling quick fault finding and debugging.Controls up to 40 pilot valves. Each AC output can have 10 pilot valves connected in parallel, enabling up to 400 pilot valves to be supported. Each DC output can have 3 pilot valves connected in parallel between −20°C to 60°C (−4°F to 140°F), enabling up to 120 pilot valves to be supported and 2 pilot valves connected in parallel between −40°C to 60°C (−40°F to 140°F), enabling up to 80 pilot valves to be supported.Conforms to the requirements of UL, CE, FCC and RCM.

Latest Comments for Goyen ISP-ACAC40-PCA Sensor


Autres produits recommandés Goyen


Goyen K0380 (M1131B) Valve Repair Kit
Goyen K0580 Solenoid Repair Kit
Goyen K2000 (M1204B) RCA20 Diaphragm
Goyen K2501 Diaphragm Kit
Goyen K2503 (M1187) RCA25 Diaphragm Repair Kit
Goyen K2529 Diaphragm Kit
Goyen K3500 Diaphragm Kit
Goyen K4502 Diaphragm Kit
Goyen N282 Solenoid Valve Coil
Goyen K7600 Diaphragm Kit
Goyen RCA45DD Dresser Nut Valve
Goyen RCA25DD4 Dresser Nut Valve
Goyen RCAC25FS4 Flanged Valve
Goyen RCA76MM Manifold Flat Mount Valve
Goyen RCA 10-6T Threaded Valve
Goyen RCAC 25T4 Threaded Valve
Goyen RCA 76T Threaded Valve
Goyen 3-6VFD Enclosure Hazardous Locations