MOELLER XPOLE PL7 B25/1 Miniature circuit breaker
MOELLER
Numéro de produit: XPOLE PL7 B25/1
Artikelnummer: 262678
Fabricant: MOELLER
Confirmed Rating:
☆☆☆☆☆
☆ (3.1)
Rating Count: 12716
Veuillez contacter notre équipe d'assistance en direct ou remplir le formulaire d'offre en ligne pour obtenir des informations détaillées sur le produit MOELLER XPOLE PL7 B25/1 MOELLER XPOLE PL7 B25/1 Miniature circuit breaker Nous reviendrons vers vous dès que possible.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for MOELLER XPOLE PL7 B25/1 Miniature circuit breaker
Description for MOELLER XPOLE PL7 B25/1 Miniature circuit breaker
TECHNICAL DATAElectricalRated switching capacity according to IEC/EN 60898-1 [Icn]10 kADESIGN VERIFICATION AS PER IEC/EN 61439Technical data for design verificationRated operational current for specified heat dissipation [In]25 AHeat dissipation per pole, current-dependent [Pvid]0 WEquipment heat dissipation, current-dependent [Pvid]3 WStatic heat dissipation, non-current-dependent [Pvs]0 WHeat dissipation capacity [Pdiss]0 WOperating ambient temperature min.-25 °COperating ambient temperature max.+75 °Clinear, per +1 °C, results in a 0.5% reduction of current carrying capacityIEC/EN 61439 design verification10.2 Strength of materials and parts10.2.2 Corrosion resistanceMeets the product standard's requirements.10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effectsMeets the product standard's requirements.10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2 Strength of materials and parts10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.10.2 Strength of materials and parts10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.2 Strength of materials and parts10.2.7 InscriptionsMeets the product standard's requirements.10.3 Degree of protection of ASSEMBLIESDoes not apply, since the entire switchgear needs to be evaluated.10.4 Clearances and creepage distancesMeets the product standard's requirements.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.10.8 Connections for external conductorsIs the panel builder's responsibility.10.9 Insulation properties10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.10.9 Insulation properties10.9.3 Impulse withstand voltageIs the panel builder's responsibility.10.9 Insulation properties10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.TECHNICAL DATA ETIM 7.0Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss10.0.1-27-14-19-01 [AAB905014])Release characteristicBNumber of poles (total)1Number of protected poles1Rated current25 ARated voltage230 VRated insulation voltage Ui440 VRated impulse withstand voltage Uimp4 kVRated short-circuit breaking capacity Icn EN 60898 at 230 V10 kARated short-circuit breaking capacity Icn EN 60898 at 400 V10 kARated short-circuit breaking capacity Icu IEC 60947-2 at 230 V0 kARated short-circuit breaking capacity Icu IEC 60947-2 at 400 V0 kAVoltage typeACFrequency50 - 60 HzCurrent limiting class3Suitable for flush-mounted installationNoConcurrently switching N-neutralNoOver voltage category3Pollution degree2Additional equipment possibleYesWidth in number of modular spacings1Built-in depth70.5 mmDegree of protection (IP)IP20Ambient temperature during operating-25 - 55 °CConnectable conductor cross section multi-wired1 - 25 mm²Connectable conductor cross section solid-core1 - 25 mm²
Latest Comments for MOELLER XPOLE PL7 B25/1 Miniature circuit breaker
Autres produits recommandés MOELLER