SICK 6028429 type: WF5-40B410 Fork sensor

Accédez aux informations sur le stock, la livraison et les prix du produit SICK 6028429 type: WF5-40B410 Fork sensor avec marque SICK. SICK, 6028429, SICK 6028429, type:, SICK type:, 6028429 type:, SICK 6028429 type:, WF5-40B410
Pour obtenir une offre maintenant: info@industrialmaterialcenter.com
Numéro de produit WF5-40B410
Fabricant SICK

Description: WF5-40B410 ( SICK )

SICK 6028429 type: WF5-40B410 Fork sensor



Product Name: SICK 6028429 type: WF5-40B410 Fork sensor
Product Brand: SICK
Product Code: WF5-40B410
Product Artikel: SICK 6028429 type: WF5-40B410 Fork sensor
FEATURES Functional principle Optical detection principle Dimensions (W x H x D) 10 mm x 35 mm x 57 mm Housing design (light emission) Fork shaped Fork width 5 mm Fork depth 42 mm Minimum detectable object (MDO) 0.2 mm Label detection ✔ Light source LED, Infrared light Wave length 850 nm Adjustment Plus/minus button (Sensitivity, light/dark switching, key lock) Teach-in mode — Output function Light/darkswitching, selectable via button MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple < 10 %  2) Power consumption 40 mA Switching frequency 10 kHz  3) Response time 100 µs Stability of response time ± 20 µs Jitter 40 µs Switching output PNP/NPN Switching output (voltage) PNP: HIGH = V S – ≤ 2 V / LOW approx. 0 V NPN: HIGH = approx. V S  / LOW ≤ 2 V Switching output Light/dark switching Output current I max. 100 mA Initialization time 100 ms Connection type Male connector M8, 4-pin Ambient light immunity Sunlight: ≤ 10,000 lx Protection class III  4) Circuit protection U V  connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression Enclosure rating IP65 Weight Approx. 36 g ... 160 g  5) Housing material Metal, Aluminum 1)  Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  With light/dark ratio 1:1. 4)  Reference voltage DC 50 V. 5)  Depending on fork width. AMBIENT DATA Ambient operating temperature –20 °C ... +60 °C  1) Ambient storage temperature –30 °C ... +80 °C Shock load According to EN 60068-2-27 UL File No. NRKH.E191603 1)  Do not bend below 0 °C. CLASSIFICATIONS ECl@ss 5.0 27270909 ECl@ss 5.1.4 27270909 ECl@ss 6.0 27270909 ECl@ss 6.2 27270909 ECl@ss 7.0 27270909 ECl@ss 8.0 27270909 ECl@ss 8.1 27270909 ECl@ss 9.0 27270909 ETIM 5.0 EC002720 ETIM 6.0 EC002720 UNSPSC 16.0901 39121528

Autres produits recommandés SICK