SICK 1049056 type: WL9-3P1132 Small photoelectric sensors

Accédez aux informations sur le stock, la livraison et les prix du produit SICK 1049056 type: WL9-3P1132 Small photoelectric sensors avec marque SICK. SICK, 1049056, SICK 1049056, type:, SICK type:, 1049056 type:, SICK 1049056 type:
Pour obtenir une offre maintenant: info@industrialmaterialcenter.com
Numéro de produit WL9-3P1132
Fabricant SICK

Description: WL9-3P1132 ( SICK )

SICK 1049056 type: WL9-3P1132 Small photoelectric sensors



Product Name: SICK 1049056 type: WL9-3P1132 Small photoelectric sensors
Product Brand: SICK
Product Code: WL9-3P1132
Product Artikel: SICK 1049056 type: WL9-3P1132 Small photoelectric sensors
FEATURES Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation Dimensions (W x H x D) 12.2 mm x 50 mm x 23.6 mm Housing design (light emission) Rectangular Mounting hole M3 Sensing range max. 0 m ... 5 m  1) Sensing range 0 m ... 3 m  1) Type of light Visible red light Light source PinPoint LED  2) Light spot size (distance) Ø 45 mm (1.5 m) Wave length 650 nm Adjustment Single teach-in button 1)  Reflector PL80A. 2)  Average service life: 100,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple pp   2) Power consumption 30 mA  3) Switching output PNP  4) Output function Complementary Switching mode Light/dark switching  4) Output current I max. ≤ 100 mA  5) Response time 6) Switching frequency 1,000 Hz  7) Connection type Cable, 4-wire, 2 m  8) Cable material PVC Conductor cross-section 0.14 mm² Circuit protection A  9) B  10) C  11) Protection class III Weight 80 g Polarisation filter ✔ Housing material Plastic, VISTAL® Optics material Plastic, PMMA Enclosure rating IP66 IP67 IP69K Ambient operating temperature –40 °C ... +60 °C Ambient storage temperature –40 °C ... +75 °C UL File No. NRKH.E181493 1)  Limit values when operated in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  Without load. 4)  Q = light switching. 5)  At and above Tu 50 °C, a max. load current of Imax. = 50 mA is permitted. 6)  Signal transit time with resistive load. 7)  With light/dark ratio 1:1. 8)  Do not bend below 0 °C. 9)  A = V S  connections reverse-polarity protected. 10)  B = inputs and output reverse-polarity protected. 11)  C = interference suppression. CLASSIFICATIONS ECl@ss 5.0 27270902 ECl@ss 5.1.4 27270902 ECl@ss 6.0 27270902 ECl@ss 6.2 27270902 ECl@ss 7.0 27270902 ECl@ss 8.0 27270902 ECl@ss 8.1 27270902 ECl@ss 9.0 27270902 ECl@ss 10.0 27270902 ECl@ss 11.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 UNSPSC 16.0901 39121528

Autres produits recommandés SICK