industrialmaterialcenter.com

Gestra SRL6-50

Gestra

Product number: SRL6-50
Producer: Gestra
Confirmed Rating: ☆☆☆☆☆☆ (4.5)
Rating Count: 5152

You can fill in the online quotation form or get in touch with Live Support Team for the Gestra brand, SRL6-50 product. We will get back to you as soon as possible.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Gestra SRL6-50

Description for Gestra SRL6-50

Description If the level electrode (high or low level limiter) is installed in an isolatable level pot outside the boiler, make sure that the level pot is drained and the connecting lines are rinsed at regular intervals. For this purpose the connecting lines must be shut off and opened at regular intervals and by opening and closing the drain valve the lines and the level pot will be rinsed. The logic unit is designed to be used in conjunction with level switch NRS 1-50 (water level limiter) or level switch NRS 1-51 (high level alarm) to monitor the correct timing and sequence of valve operations. During the rinsing process the level switch jumpers the level electrode, thus preventing the safety or control circuit from opening. The level switch - controlled by the logic unit - also monitors the rinsing and bypass time. Function The logic unit monitors the following times and process se - quences: Interval time: This is the time interval at which, depending on the operating mode (24h / 72h boiler operation without constant supervision), the connecting lines have to be rinsed. During operation the standby time is started after the in - terval time has elapsed and the interval time is reset to its initial value (24h/72h). During the standby time the connecting lines must be rinsed. Synchronizing: When valve D or E closes the purging time starts and the interval time is reset to 24h/72h. The purging time can start any time. The purging time can also start after the stand-by time has elapsed. After the purging time has started the stand-by input of the level switch NRS 1-50, NRS 1-51 will also be activated. During the purging time all valves must be opened and closed in a fixed sequence. The logic unit polls the limit switches to obtain data on the valve positions and the level electrode for information on the water level (low level if electrode is exposed). If valves D and E are open after the rinsing process and valve F closed and the level electrode for low water (low level) is submerged again, the stand-by input of the level switch will be deactivated. The stand-by time of the level switch is limited to a maxi - mum of 5 minutes. If the stand-by input is not deactivated by the logic unit during this time, the level switch will open the safety or control circuit

Latest Comments for Gestra SRL6-50


Other Recommended Products Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART