Grünewald SMALL-Ex Series Level Measuring For Closed Tanks Without Pressure Compensation
Grünewald
Product number: SMALL-Ex Series Level Measuring For Closed Tanks Without Pressure Compensation
Producer: Grünewald
Confirmed Rating:
☆☆☆☆☆ ()
Rating Count:
You can fill in the online quotation form or get in touch with Live Support Team for the Grünewald brand, SMALL-Ex Series Level Measuring For Closed Tanks Without Pressure Compensation product. We will get back to you as soon as possible.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for Grünewald SMALL-Ex Series Level Measuring For Closed Tanks Without Pressure Compensation
Description for Grünewald SMALL-Ex Series Level Measuring For Closed Tanks Without Pressure Compensation
This specialized level measuring device has been developed especially for the use in pressurized tanks. Two pressure sensors separately monitor the level and the internal pressure of the tank ensuring an exact measurement independent of the internal pressure that may be inside of the tank up to a maximum of 1 bar.A pressure sensor is installed at the top of the device and evaluates the level of liquid in the tank. On tanks that have an internal pressure fluctuations (e.g., poor ventilation or fluid back flow), over-pressurization may take place that will affect the measurement.. To compensate for this, a second pressure sensor monitors the internal tank air pressure and calculates this internally. The internal communication through the data BUS calculates both measured values and a precise measuring result, independent of the surrounding pressure is transferred to the device.Using this measuring method, it is possible to achieve precise measurements under heavy duty operation. Susceptible mechanics are excluded. Marking:Certifications: Env. Tempemperature: Housing Material: Gauge Accuracy: Medium Illuminated Display: Display: Output Signal: Nominal Voltage: I Ex ia I MaEx ia I MaPO Ex ia I Ma XBVS 06 ATEX E005 XIECEx BVS 09.0056XIECEx TSA 13.0023XMSHA 18-ISA 150004-0TC RU C-DE.M?62.B.03774MA J2012330, J2012329 -50 to +100 °C bei Gruppe I-50 to +80 °C bei Gruppe II Stainless Steel +/- 0,5% from end-value (higher accuracy on request) fluid medium, e.g. water, emulsion, oil optional mm; m; %; ft (other units on reauest) 5 - 15Hz0/4 - 20mA * - **V (max. 10 V DC, at min. 7,5V power supply) CAN-Bus 12V DC (7,5 – 14,0 V DC) 3-wiring technology16V DC (9,6 – 16,1 V DC) 3-wiring technology24V DC (14 – 26,6 V DC) 2-wiring technology
Latest Comments for Grünewald SMALL-Ex Series Level Measuring For Closed Tanks Without Pressure Compensation
Other Recommended Products Grünewald