Goyen IS-ACDC12 Sensor

Per la marca di Goyen che una Goyen IS-ACDC12 Sensor cosi lo rispondiamo subito per le vostre domande se in magazzino oppure la consegna e anche il prezzo. Poi facciamo la consegna in tutto il mondo! Goyen, IS-ACDC12, Goyen IS-ACDC12, , Goyen , IS-ACDC12 , Goyen IS-ACDC12 , Sensor, Goyen Sensor, IS-ACDC12 Sensor
Si prega di chiedere un'offerta: info@industrialmaterialcenter.com
Il codice del prodotto IS-ACDC12
Produttori Goyen

Description: IS-ACDC12 ( Goyen )

Goyen IS-ACDC12 Sensor



Product Name: Goyen IS-ACDC12 Sensor
Product Brand: Goyen
Product Code: IS-ACDC12
Product Artikel: Goyen IS-ACDC12 Sensor
Integrato Sequencer AC-IN DC-OUT 12-0/P EN - No dP Sensor The Integrato Sequencer (IS & ISP) features integrated controls intended for use with larger reverse pulse jet filter cleaning systems. The IS & ISP have been designed to operate across a wide range of environmental conditions. It is suitable for use with all types of filters, including bags, cartridges, sintered metal or ceramic filters. Features & Specifications: DP SUPPORT : 0 to 4.5 kPa INPUT VOLTAGE AC: 100/240 V @ 50/60 Hz OUTPUT VOLTAGE AC: 100/240 V @ 50/60 Hz (same as input), DC: 24 V MAXIMUM INPUT POWER : AC IN, AC OUT Model: 225 W, AC IN, DC OUT Model: 65 W DISCRETE SOLENOID OUTPUTS : 12, 20 or 40 outputs ENCLOSURE : Polycarbonate or no enclosure PROTECTION RATING (LARGE ENCLOSURE) : Polycarbonate: IP 66/67 & NEMA 1, 3, 3S, 4, 4X, 6, 6P & 12 PROTECTION RATING (SMALL ENCLOSURE) : Polycarbonate: IP65 & NEMA 1, 4, 4X, 12 & 13 OPERATING TEMPERATURE : −40°C to 60°C (−40°F to 140°F) ON & OFF TIME ON : 30 ms to 1000 ms, OFF: 1 s to 1000 s INPUTS Voltage Free : Fan Stop, Low Header Alarm OUTPUTS Voltage Free : Coil Error Analogue Output : 4–20 mA dP signal on the ISP Low temperature operation −40°C (−40°F) Automatic valve detection. Voltage-free coil error output and a visual indication on the display showing which pilot valve output has an error, enabling quick fault finding and debugging. Controls up to 40 pilot valves. Each AC output can have 10 pilot valves connected in parallel, enabling up to 400 pilot valves to be supported. Each DC output can have 3 pilot valves connected in parallel between −20°C to 60°C (−4°F to 140°F), enabling up to 120 pilot valves to be supported and 2 pilot valves connected in parallel between −40°C to 60°C (−40°F to 140°F), enabling up to 80 pilot valves to be supported. Conforms to the requirements of UL, CE, FCC and RCM.

Altri prodotti consigliati Goyen