industrialmaterialcenter.com

Hydac DRV25 Needle Valves

Hydac

Il codice del prodotto: DRV25
Artikelnummer: Art.Nr. 505111705574
Produttori: Hydac
Confirmed Rating: ☆☆☆☆☆ (3.7)
Rating Count: 13402

Contattate il nostro team per la marca Hydac il codice DRV25 per ulteriori informazioni sul prodotto. Compilate anche un modulo di preventivo online. Ti risponderemo al più presto.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Hydac DRV25 Needle Valves

Description for Hydac DRV25 Needle Valves

Needle Valves with and without Reverse Flow Check Direct-Acting Inline Mounted - 350 bar DV- / DRV- 06 to 16·         For regulating the speed of loads ·         For fine adjustment and shut-off of the flow ·         For system-related damping in hydraulic circuits ·         To release pressure from accumulator systems ·         As an emergency drain for lowering a load without a dead man's circuit ·         Spindle secured before complete loosening ·         An Allen set-screw locks the setting of the knob ·         Choice of five sizes ensures best possible adaptability to the system ·         Drop forged housings with high safety factor Operating pressure: max. 350 bar Nominal flow: DV- / DRV-06 max. 20 l/min DV- / DRV-08 max. 50 l/min DV- / DRV-10 max. 60 l/min DV- / DRV-12 max. 90 l/min DV- / DRV-16 max. 180 l/min Cracking pressure (DRV): 0.5 bar Media operating temperature range: min. -20 °C to max. +100 °C Ambient temperature range: min. -20 °C to max. +100 °C Operating fluid: Hydraulic oil to DIN 51524 Part 1, 2 and 3 Viscosity range: min. 2.8 mm²/s to max. 800 mm²/s Filtration: Class 21/19/16 according to ISO 4406 or cleaner Installation: no orientation restrictions, preferably horizontal Materials: Valve body: steel Piston: hardened and ground steel Seals: FKM (standard) Back-up rings: PTFE Weight: DV-06 = 0.10 kg DRV-06 = 0.10 kg DV-08 = 0.26 kg DRV-08 = 0.28 kg DV-10 = 0.38 kg DRV-10 = 0.41 kg DV-12 = 0.62 kg DRV-12 = 0.65 kg DV-16 = 1.04 kg DRV-16 = 1.14 kgThe DV is an inline mounted flow control valve which controls the flow by adjusting the cross-section. The flow rate is therefore dependent on the pressure differential and viscosity. Starting with the throttle spindle in the fully closed position, the flow rate increases in accordance with the appropriate curve as the control knob is turned. The flow is controlled in both directions. The scale on the lower edge of the control knob enables accurate repeat setting. The DRV is a flow control valve in the same design which also allows the same fine flow adjustment, but in one direction only. Unrestricted flow in the reverse direction is via the built-in check valve (cracking pressure 0.5 bar).

Latest Comments for Hydac DRV25 Needle Valves


Altri prodotti consigliati Hydac


Hydac 0030 D 010 BH4HC Filter Element
Hydac 0030 D 020 BH4HC Filter Element
Hydac 0030 D 020 BH4HC Filter Element
Hydac 0030 R 010 BN4HC Filter Element
Hydac 0060 D 0005 BH4HC Filter Element
Hydac 0060 D 010 BH4HC Filter Element
Hydac 0060 D 020 BH4HC Filter Element
Hydac 0060 R 010 BN4HC Filter Element
Hydac 0060 R 020 BN4HC Filter Element
Hydac 0110 D 005 BH4HC Filter Element
Hydac 0110 D 010 BH4HC Filter Element
Hydac 0110 D 010 BH4HC Filter Element
Hydac 0110 D 020 BH4HC Filter Element
Hydac 0110 R 010 BN4HC Filter Element
Hydac 0110 R 020 BN4HC Filter Element
Hydac 0160 D 010 BH4HC Filter Element
Hydac 0160 D 020 BH4HC Filter Element
Hydac 0160 R 010 BN4HC Filter Element