industrialmaterialcenter.com

MOELLER XPOLE PL7 B25/1 Miniature circuit breaker

MOELLER

Il codice del prodotto: XPOLE PL7 B25/1
Artikelnummer: 262678
Produttori: MOELLER
Confirmed Rating: ☆☆☆☆☆ (3.1)
Rating Count: 12716

Contattate il nostro team per la marca MOELLER il codice XPOLE PL7 B25/1 per ulteriori informazioni sul prodotto. Compilate anche un modulo di preventivo online. Ti risponderemo al più presto.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for MOELLER XPOLE PL7 B25/1 Miniature circuit breaker

Description for MOELLER XPOLE PL7 B25/1 Miniature circuit breaker

TECHNICAL DATAElectricalRated switching capacity according to IEC/EN 60898-1 [Icn]10 kADESIGN VERIFICATION AS PER IEC/EN 61439Technical data for design verificationRated operational current for specified heat dissipation [In]25 AHeat dissipation per pole, current-dependent [Pvid]0 WEquipment heat dissipation, current-dependent [Pvid]3 WStatic heat dissipation, non-current-dependent [Pvs]0 WHeat dissipation capacity [Pdiss]0 WOperating ambient temperature min.-25 °COperating ambient temperature max.+75 °Clinear, per +1 °C, results in a 0.5% reduction of current carrying capacityIEC/EN 61439 design verification10.2 Strength of materials and parts10.2.2 Corrosion resistanceMeets the product standard's requirements.10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effectsMeets the product standard's requirements.10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2 Strength of materials and parts10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.10.2 Strength of materials and parts10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.2 Strength of materials and parts10.2.7 InscriptionsMeets the product standard's requirements.10.3 Degree of protection of ASSEMBLIESDoes not apply, since the entire switchgear needs to be evaluated.10.4 Clearances and creepage distancesMeets the product standard's requirements.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.10.8 Connections for external conductorsIs the panel builder's responsibility.10.9 Insulation properties10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.10.9 Insulation properties10.9.3 Impulse withstand voltageIs the panel builder's responsibility.10.9 Insulation properties10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.TECHNICAL DATA ETIM 7.0Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss10.0.1-27-14-19-01 [AAB905014])Release characteristicBNumber of poles (total)1Number of protected poles1Rated current25 ARated voltage230 VRated insulation voltage Ui440 VRated impulse withstand voltage Uimp4 kVRated short-circuit breaking capacity Icn EN 60898 at 230 V10 kARated short-circuit breaking capacity Icn EN 60898 at 400 V10 kARated short-circuit breaking capacity Icu IEC 60947-2 at 230 V0 kARated short-circuit breaking capacity Icu IEC 60947-2 at 400 V0 kAVoltage typeACFrequency50 - 60 HzCurrent limiting class3Suitable for flush-mounted installationNoConcurrently switching N-neutralNoOver voltage category3Pollution degree2Additional equipment possibleYesWidth in number of modular spacings1Built-in depth70.5 mmDegree of protection (IP)IP20Ambient temperature during operating-25 - 55 °CConnectable conductor cross section multi-wired1 - 25 mm²Connectable conductor cross section solid-core1 - 25 mm²

Latest Comments for MOELLER XPOLE PL7 B25/1 Miniature circuit breaker


Altri prodotti consigliati MOELLER


MOELLER DIL EM-10-G Contactor
MOELLER XPOLE PL7 B25/1 Miniature circuit breaker
MOELLER XPOLE PL7 C2/3 Circuit-breaker
MOELLER XIOC-BP-2 XIOC module
MOELLER XC-CPU201-EC256K-8DI-6DO Modular PLC
MOELLER XIOC-16DI Signal Module
MOELLER ESR4-N0-31 Safety Relay
MOELLER DIL ER-22-G Mini Contactor
MOELLER FAZ-3-B6 Miniature Circuit Breaker
MOELLER FAZ-B6/1-SP Circuit Breaker
MOELLER DIL ET 70 Timer
MOELLER 289963 DE51-LZ3-007-V4 Drive
MOELLER PKZM0-10-C Motor protective circuit breaker
MOELLER PKZM0-1-C Motor-protective circuit-breaker
MOELLER DILM 9-01 Pole Contactor