MOELLER XPOLE PL7 C2/3 Circuit-breaker
MOELLER
Il codice del prodotto: XPOLE PL7 C2/3
Artikelnummer: Catalog No. 263404
Produttori: MOELLER
Confirmed Rating:
☆☆☆☆☆☆
(4.2)
Rating Count: 10304
Contattate il nostro team per la marca MOELLER il codice XPOLE PL7 C2/3 per ulteriori informazioni sul prodotto. Compilate anche un modulo di preventivo online. Ti risponderemo al più presto.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for MOELLER XPOLE PL7 C2/3 Circuit-breaker
Description for MOELLER XPOLE PL7 C2/3 Circuit-breaker
Technical dataElectricalRated switching capacity according to IEC/EN 60898-1 Icn kA 10Design verification as per IEC/EN 61439Technical data for design verificationRated operational current for specified heat dissipation In A 2Heat dissipation per pole, current-dependent Pvid W 0Equipment heat dissipation, current-dependent Pvid W 4.1Static heat dissipation, non-current-dependent Pvs W 0Heat dissipation capacity Pdiss W 0Operating ambient temperature min. °C -25Operating ambient temperature max. °C 75linear, per +1 °C, results in a 0.5% reduction of current carrying capacityIEC/EN 61439 design verification10.2 Strength of materials and parts10.2.2 Corrosion resistance Meets the product standard's requirements.10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.10.2.3.3 Verification of resistance of insulating materials to abnormal heatand fire due to internal electric effectsMeets the product standard's requirements.10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.10.2.7 Inscriptions Meets the product standard's requirements.10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.10.4 Clearances and creepage distances Meets the product standard's requirements.10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.10.7 Internal electrical circuits and connections Is the panel builder's responsibility.10.8 Connections for external conductors Is the panel builder's responsibility.10.9 Insulation properties10.9.2 Power-frequency electric strength Is the panel builder's responsibility.10.9.3 Impulse withstand voltage Is the panel builder's responsibility.10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton willprovide heat dissipation data for the devices.10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must beobserved.04/24/2020 Eaton 263404 ED2020 V67.0 EN 1 / 210.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must beobserved.10.13 Mechanical function The device meets the requirements, provided the information in the instructionleaflet (IL) is observed.Technical data ETIM 7.0Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB)(ecl@ss10.0.1-27-14-19-01 [AAB905014])Release characteristic CNumber of poles (total) 3Number of protected poles 3Rated current A 2Rated voltage V 400Rated insulation voltage Ui V 440Rated impulse withstand voltage Uimp kV 4Rated short-circuit breaking capacity Icn EN 60898 at 230 V kA 10Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA 10Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA 0Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kA 0Voltage type ACFrequency Hz 50 - 60Current limiting class 3Suitable for flush-mounted installation NoConcurrently switching N-neutral NoOver voltage category 3Pollution degree 2Additional equipment possible YesWidth in number of modular spacings 3Built-in depth mm 70.5Degree of protection (IP) IP20Ambient temperature during operating °C -25 - 55Connectable conductor cross section multi-wired mm² 1 - 25 Connectable conductor cross section solid-core mm² 1 - 25
Latest Comments for MOELLER XPOLE PL7 C2/3 Circuit-breaker
Altri prodotti consigliati MOELLER