SICK 6024917 type: UE10-3OS2D0 Safety relay

Per la marca di SICK che una SICK 6024917 type: UE10-3OS2D0 Safety relay cosi lo rispondiamo subito per le vostre domande se in magazzino oppure la consegna e anche il prezzo. Poi facciamo la consegna in tutto il mondo! SICK, 6024917, SICK 6024917, type:, SICK type:, 6024917 type:, SICK 6024917 type:, UE10-3OS2D0
Si prega di chiedere un'offerta: info@industrialmaterialcenter.com
Il codice del prodotto UE10-3OS2D0
Produttori SICK

Description: UE10-3OS2D0 ( SICK )

SICK 6024917 type: UE10-3OS2D0 Safety relay



Product Name: SICK 6024917 type: UE10-3OS2D0 Safety relay
Product Brand: SICK
Product Code: UE10-3OS2D0
Product Artikel: SICK 6024917 type: UE10-3OS2D0 Safety relay
SAFETY-RELATED PARAMETERS Safety integrity level SIL3 (IEC 61508)  1) SILCL3 (EN 62061)  1) Category Category 4 (EN ISO 13849)  1) Performance level PL e (EN ISO 13849)  1) B 10d  parameter 1.26 x 10 6  switching cycles (AC-15, 230 V, I = 1.5 A) 5.9 x 10 6  switching cycles (AC-15, 230 V, I = 0.75 A) 4.35 x 10 5  switching cycles (DC-13, 24 V, I = 2.5 A) 1 x 10 7  switching cycles (DC-13, 24 V, I = 0.63 A) PFH D  (mean probability of a dangerous failure per hour) 3.0 x 10 -8  (EN ISO 13849) T M  (mission time) 20 years (EN ISO 13849) 1)  If the feedback current path Y1 - Y2 (external device monitoring) is monitored using an appropriate main unit. INTERFACES Connection type Fixed screw terminals Number of enabling current paths (N/O) 3, relevant for safety ELECTRICAL DATA - OPERATING DATA Voltage supply B1-B2/B3-B4 Output circuit > 25 V AC / 60 V DC PELV Output circuit ≤ 25 V AC / 60 V DC PELV or SELV Power consumption 2.4 W (DC) Overvoltage category III (see operating instructions) Rated insulation voltage U i 300 V AC Rated impulse withstand voltage U imp 4 kV Test voltage 2 kV (50 Hz) (EN 60439-1) ELECTRICAL DATA - INPUT CIRCUITS: B1-B2/B3-B4 Input voltage 24 V DC (15 V DC ... 30 V DC) Input current ≤ 500 mA ELECTRICAL DATA - OUTPUT CURRENT PATHS: 13/14, 23/24, 33/34, 41/42, Y1/Y2 Response time (≤ 20 ms)  1) Number of enabling current paths (N/O) 3, relevant for safety Number of signaling current paths (N/C) 1, not safety-relevant Number of feedback current paths (N/C) 1, external device monitoring (EDM) Contact type Positively driven Contact material Silver alloy, gold flashed Switching voltage Enabling current path 10 V AC ... 230 V AC 10 V DC ... 300 V DC Signaling current path 10 V AC ... 230 V AC 10 V DC ... 300 V DC Feedback current path 10 V DC ... 24 V DC Current-carrying capacity per OSSD Enabling current path 5 mA ... 6 A Signaling current path 5 mA ... 6 A Feedback current path 5 mA ... 100 mA Total current ≤ 12 A Usage category AC-15/DC-13 (EN 60947-5-1) Rated operating current (voltage) 4 A (230 V AC) 360 switching cycles/h 3 A (230 V AC) 3600 switching cycles/h 4 A (24 V DC) 360 switching cycles/h 2.5 A (24 V DC) 3600 switching cycles/h Mechanical life (relay contacts) 1 x 10 7  switching cycles Electrical life (relay contacts) 2 x 10 6  switching cycles 1)  K1/K2. MECHANICAL DATA Dimensions (W x H x D) 22.5 mm x 114 mm x 96.5 mm Weight 0.2 kg CLASSIFICATIONS ECl@ss 5.0 27371990 ECl@ss 5.1.4 27371990 ECl@ss 6.0 27371819 ECl@ss 6.2 27371819 ECl@ss 7.0 27371819 ECl@ss 8.0 27371819 ECl@ss 8.1 27371819 ECl@ss 9.0 27371819 ECl@ss 10.0 27371819 ECl@ss 11.0 27371819 ETIM 5.0 EC001449 ETIM 6.0 EC001449 ETIM 7.0 EC001449 UNSPSC 16.0901 41113704

Altri prodotti consigliati SICK