Datasheets for SICK 6034535 type: UE23-3MF2D2 Safety Relay

Description for SICK 6034535 type: UE23-3MF2D2 Safety Relay

SAFETY-RELATED PARAMETERSSafety integrity levelSILCL2 (EN 62061)CategoryCategory 3 (EN ISO 13849)Performance levelPL d (EN ISO 13849)B10d parameter3 x 105 switching cycles (AC-15, 230 V, I = 5 A)2 x 106 switching cycles (DC-15, 230 V, I = 2 A)7 x 106 switching cycles (DC-13, 24 V, I = 1 A)PFHD (mean probability of a dangerous failure per hour)2.0 x 10-7 (EN ISO 13849)TM (mission time)20 years (EN ISO 13849)Stop category0 (EN 60204-1)INTERFACESConnection typeFixed screw terminalsNumber of enabling current paths (N/O)3, relevant for safetyELECTRICAL DATA - OPERATING DATASupply voltage VSA1, A224 V DC (19.2 V DC ... 30 V DC)Residual ripple(≤ 2.4 Vpp) 1)Power consumption(≤ 1 W)Overvoltage categoryIIRated insulation voltage Ui300 V ACRated impulse withstand voltage Uimp4 kVTest voltage2.2 kV (50 Hz) (EN 60439-1)1) In DC operation, within the limits of VS.ELECTRICAL DATA - CONTROL VOLTAGE: Y1 - Y2 - Y3Control voltageUV - 2 V DC ... UVControl current≤ 20 mAShort-circuit current≤ 250 mAShort-circuit protection8 A gG, with tripping characteristics B or CReset timeManual≤ 70 msAutomatic≤ 600 msELECTRICAL DATA - OUTPUT CURRENT PATHS: 13/14, 23/24, 31/32Response time(≤ 80 ms) 1)Number of enabling current paths (N/O)3, relevant for safetyNumber of signaling current paths (N/C)1, not safety-relevantContact typePositively drivenContact materialSilver alloy, gold flashedSwitching voltageEnabling current path5 V AC ... 230 V AC5 V DC ... 300 V DCSignaling current path5 V AC ... 230 V AC5 V DC ... 300 V DCCurrent-carrying capacity per OSSDEnabling current path10 mA ... 8 ASignaling current path10 mA ... 5 AUsage categoryAC-15/DC-13 (EN 60947-5-1)Rated operating current (voltage)5 A (230 V AC) 360 switching cycles/h5 A (24 V DC) 360 switching cycles/hSwitching frequency≤ 3600/hMechanical life (relay contacts)1 x 107 switching cyclesElectrical life (relay contacts)1 x 106 switching cycles1) K1/K2.MECHANICAL DATADimensions (W x H x D)22.5 mm x 123 mm x 93.5 mmWeight0.2 kgCLASSIFICATIONSECl@ss 5.027371990ECl@ss 5.1.427371990ECl@ss 6.027371819ECl@ss 6.227371819ECl@ss 7.027371819ECl@ss 8.027371819ECl@ss 8.127371819ECl@ss 9.027371819ECl@ss 10.027371819ECl@ss 11.027371819ETIM 5.0EC001449ETIM 6.0EC001449ETIM 7.0EC001449UNSPSC 16.090141113704

Latest Comments for SICK 6034535 type: UE23-3MF2D2 Safety Relay


Altri prodotti consigliati SICK


SICK WL11-2P2432
SICK 1044442 WTB11-2P2461 Photoelectric Proximity Sensor
SICK WL27-2F431
SICK VL 18-3P3140
SICK VSPI-2F111
SICK DGS60-C1A02500
SICK 1028934 TYPE: S30A-4011BA Safety laser scanner
SICK CVS1-P112
SICK S30A-6111CL
SICK UE48-3OS2D2
SICK CSM1-P1114
SICK MSLE03-14061A + MSLS03-14021
SICK FGSS1500-11 + FGSE1500-11
SICK FGSS1500-11
SICK FGSS750-11
SICK WS11-2D2430
SICK S30A-7111CP
SICK UE 10-30S2D0