Ayvaz AFBT Flash Vessel Tank Systems

Ayvaz

제품 번호: AFBT
프로듀서: Ayvaz
Confirmed Rating: ☆☆☆☆ ☆☆ (2.3)
Rating Count: 9091

온라인 견적 양식을 작성하거나 라이브 지원팀에 연락하여 다음과 같이 문의할 수 있습니다. Ayvaz 브랜드, AFBT 제품입니다. 최대한 빠른 시일 내에 연락드리겠습니다.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Ayvaz AFBT Flash Vessel Tank Systems

Description for Ayvaz AFBT Flash Vessel Tank Systems

Things To Be Careful About Choosing Flash Vessel Tank: Saturated steam, which evaporates from the heat transfer surfaces, is converted into condensate at the same pressure. The enthalpy of saturated water at 1 bar pressure is 505 kJ / kg. If the condensate at 6 bar pressure is released by 1 bar the energy output will be 697-505 = 192 kJ / kg. This energy evaporates some of the condensate to steam.This steam is Flash Steam.Why Flash Steam is Important?It includes too much energy and it can be mount to different installation areas.If Flash Steam drains to the atmosphere there will be waste energy and effeciency lost.Acquiring Flash SteamWhen the water is heated under atmospheric pressure, the temperature rises up to 100 °C.The heat to be given does not increase the temperature, but it converts water to steam.The heat absorbed by the water during the rising of the temperature to the boiling point is called Inchsensible heatInch or “saturated liquid heat”. At the same temperature, the heat required to turn the water at the boiling point into steam is called Inchlatent heatInch.The amount of heat required to increase 1 kg of water temperature by 1 ° C in the atmospheric pressure is 4,186 kJThe saturated liquid temperature of the condensate at steam temperature and pressure of 8 bar is 721 kJ / kg (saturated steam table).If this condensate is leaked to a 2 bar tank, the heat value (saturated liquid temperature) drops to 504 kJ / kg.This is 721-504 = 217 kJ/kg of excess condensate. The percentage of the condensate to be transformed into the steam can be calculated as follows.% Flash Steam = (Q1-Q2 / q) x100Q1: Saturated liquid heat at high pressure before dischargeQ2: Saturated liquid heat of the condensate at low pressureq: The latent heat of the steam at low pressure where the condensate is drained % Flash Steam = (721-504/2201)x100 = 9.6%That is, if there is a condensate of 3000 kg;Flash Steam = 3000x9,6% = 288 kg/hFlash Steam Tanks are used to separate the flash steam from the condensate water.In order for the flash steam to move towards the top outlet at the correct speed, the diameter of the steam tank must be appropriate. This speed is about 3-5 m/s and the velocity at which water droplets can reach the bottom of the tank. In order to be efficient, the condensate inlet to the tank should be one-third of the tank neck below. The diameter of the flash steam tank should be a diameter that allows the passage of the condensate without coming into turbulence.If the difference between high and low pressure is small.The amount of steam is less than the amount of condensate. Flash steam outlet pipe selecting the diameter according to the speed will cause the tank to remain small. in which case the tank must be selected to be two diameters larger.Choosing Flash Vessel1- Maximum condensation amount is required to obtain maximum flash steam.For this reason, the capacity of steam traps must be selected carefully, taking into consideration the counterpressure. It should also be noted that in systems where temperature control valves are used, the valve will be closed and the pressure will drop.2- The amount of use of flash steam systems must be equal to the amount of flash steam.Steam can be provided by pressure drop from a higher pressure steam line when the flash steam is missing. If flash steam is excessive, some of the flash steam must be thrown out. Also, since the flash used in heating will not be needed in summer, a heat recovery system will not be necessary.Therefore, the amount of flash steam required must be prepared.3- It is beneficial if the system to be used with flash steam is close to the outlet of the condensate at high pressure. The transport of low-pressure condensate requires large diameters and will increase investment costs. In addition, the heat losses that will occur on large pipe diameters will reduce the benefits of flash buckets.

Latest Comments for Ayvaz AFBT Flash Vessel Tank Systems


기타 추천 제품 Ayvaz


Ayvaz MKSF-30 Axial Type - Lateral Type Expansion Joint
Ayvaz MKDF-30 Axial Type - Lateral Type Expansion Joint
Ayvaz MKSF-30L Axial Type - Lateral Type Expansion Joint
Ayvaz MKDF-30L Axial Type - Lateral Type Expansion Joint
Ayvaz MKSF-60L Axial Type - Lateral Type Expansion Joint
Ayvaz MKDF-60L Axial Type - Lateral Type Expansion Joint
Ayvaz MKKB-30 Axial Type - Lateral Type Expansion Joint
Ayvaz MKKB-30L Axial Type - Lateral Type Expansion Joint
Ayvaz MKKB-60L Axial Type - Lateral Type Expansion Joint
Ayvaz SEISMIC Isolation Expansion Joint
Ayvaz DSTKKB-1 District Heating Expansion Joint
Ayvaz DSTKKB-2 District Heating Expansion Joint
Ayvaz DKK-10 Rubber Expansion Joint with Double Sphere
Ayvaz VIB-FLEX Anti Vibration Hoses
Ayvaz Nano-Insulated Fan Coil Connection Hose
Ayvaz Braided and Insulated Fan Coil Connection Hose
Ayvaz Mig-Su Extensible Flexible Metal Hose
Ayvaz Indoor-flex For Domestic Natural Gas Installation