Hydac SBO-1,4-210 Diaphragm Accumulators
Hydac
제품 번호: SBO-1,4-210
Artikelnummer: Art.Nr. 3041953
프로듀서: Hydac
Confirmed Rating:
☆☆☆☆☆☆
(4.5)
Rating Count: 8977
온라인 견적 양식을 작성하거나 라이브 지원팀에 연락하여 다음과 같이 문의할 수 있습니다. Hydac 브랜드, SBO-1,4-210 제품입니다. 최대한 빠른 시일 내에 연락드리겠습니다.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for Hydac SBO-1,4-210 Diaphragm Accumulators
Description for Hydac SBO-1,4-210 Diaphragm Accumulators
Diaphragm accumulators welded typesSBO...-...E· V = 0.075 ... 4 l· pmax = 350 barTo protect your hydraulic accumulators against non-permitted temperature increase and/or excessive pressure, we recommend our safety devices. You can find further information and an online query form under: Products / hydraulic accumulator / accumulator accessories / accumulator safety devices and in the download area of the accumulator safety devices. GENERAL 1.5.1 Permitted operating pressure see Tables 3.1. and 3.2. The permitted operating pressure can differ from the nominal pressure for foreign test certificates. 1.5.2 Permitted operating temperature of the hydraulic accumulator -10 °C ... +80 °C standard design, others on request 1.5.3 Nominal volume see Tables 3.1. and 3.2. 1.5.4 Effective gas volume Corresponds to the nominal volume of the diaphragm accumulator. 1.5.5 Effective volume Volume of fluid which is available between the operating pressures p2 and p1 . 1.5.6 Gas charging All accumulators are supplied with a protective pre-charge. Higher gas pre-charge pressures are available on request (gas charging screw or sealed gas connection). Hydraulic accumulators must only be charged with nitrogen. Never use other gases. Risk of explosion! In principle, only use nitrogen of at least Class 4.0 (filtration < 3 μm). If other gases are to be used, please contact HYDAC for advice. 1.5.7 Limits for gas pre-charge pressure p0 ≤ 0.9 ● p1 For diaphragm accumulators with PTFE diaphragms, the following applies: p0tmax ≤ 200 bar for further information, see catalogue section: z HYDAC Accumulator Technology No. 3.000 1.5.8 Permitted pressure ratio Ratio of max. operating pressure p2 to gas pre-charge pressure p0 . 1.5.9 Max. flow rate of the operating fluid In order to achieve the max. flow rate given in the tables, a residual fluid volume of approx. 10 % of the effective gas volume must remain in the accumulator. The maximum fluid flow rate was determined under specific typical conditions and is not applicable in all operating conditions
Latest Comments for Hydac SBO-1,4-210 Diaphragm Accumulators
기타 추천 제품 Hydac