PHOENIX CONTACT IBS IL 24 BK-LK/45-PAC
PHOENIX CONTACT
제품 번호: IBS IL 24 BK-LK/45-PAC
프로듀서: PHOENIX CONTACT
Confirmed Rating:
☆☆☆☆☆☆
(4.8)
Rating Count: 11033
온라인 견적 양식을 작성하거나 라이브 지원팀에 연락하여 다음과 같이 문의할 수 있습니다. PHOENIX CONTACT 브랜드, IBS IL 24 BK-LK/45-PAC 제품입니다. 최대한 빠른 시일 내에 연락드리겠습니다.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for PHOENIX CONTACT IBS IL 24 BK-LK/45-PAC
Description for PHOENIX CONTACT IBS IL 24 BK-LK/45-PAC
Explanation Usage restriction EMU: class A product, see manufacturer's declaration in the loading area Back to top Dimensions Dimensional drawing Width 85 mm Height 119.8mm Depth 71.5 mm Back to top Environmental conditions Ambient temperature (operation) -25 ° C ... 55 ° C Ambient temperature (stock / transport) -25 ° C ... 85 ° C Permissible humidity (working) 75% ... 85% Permitted humidity (stock / transport) 75% ... 85% Air pressure (operation) 80 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (stock / transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Protection class IP20 Back to top General Mounting type DIN rail Color green Net weight 220 g Note on weight specifications without a receipt Back to top interfaces Description INTERBUS Connection method F-SMA connector Note about connection method Transmission rate 2 MBit / s Transmission physics FO Description Inline local bus Connection method Inline data jumper Transmission rate 2 MBit / s Back to top System limits of the bus module Number of connectable local bus devices 63 Number of devices with parameter channels 62 Number of branch terminals supported with remote bus branch is max. 15 Back to top Inline potentials Description Bus module supply UBC; The communication power is obtained from the supply of UL (7.5 V) and analog supply UANA (24 V) bus module. Supply voltage 24 V DC (via Inline connector) Supply voltage range 19.2 V DC ... 30 V DC (includes all tolerances including ripple) Current consumption type. 90 mA (without I / O terminals connected) max. 1.25 A (with max. Number of connected I / O terminals) Definition Communication power (UL) Supply voltage 7.5 V DC ± 5% Power supply max. 2 A DC (Consider weakening) Description Supply of analog modules (UANA) Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (includes all tolerances including ripple) Power supply max. 0.5 A DC (Consider weakening) Back to top Electrical isolation Test section 7.5 V communication power, 24 V analog supply, 24 V bus module supply / functional ground 500 V AC 50 Hz 1 min Back to top Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmental friendly usage time: unlimited = EFUP-e No dangerous goods above the limit value
Latest Comments for PHOENIX CONTACT IBS IL 24 BK-LK/45-PAC
기타 추천 제품 PHOENIX CONTACT