industrialmaterialcenter.com

Zpa Pecky MOED EEx Electric Actuator

Zpa Pecky

제품 번호: MOED EEx
프로듀서: Zpa Pecky
Confirmed Rating: ☆☆☆☆☆ (3.3)
Rating Count: 14655

온라인 견적 양식을 작성하거나 라이브 지원팀에 연락하여 다음과 같이 문의할 수 있습니다. Zpa Pecky 브랜드, MOED EEx 제품입니다. 최대한 빠른 시일 내에 연락드리겠습니다.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Zpa Pecky MOED EEx Electric Actuator

Description for Zpa Pecky MOED EEx Electric Actuator

The MODACT® MOED EEx electric rotary multi-turn actuators are specially intended for controlling devices by a reversing rotary motion, e.g. slide valves and valves, and, in connection with an appropriate gearbox, also flap or ball valves, and other devices for which they are suitable due to their properties.They can be operated in an environment with a danger of explosion of explosive gaseous atmosphere in zone 1 and zone 2 according to EN 60079-10 (332320). The actuators are designed as a device of group II, category 2G in compliance with standards EN 60079-0:2004, EN 60079-1:2004, and EN 60079-7:2004 for explosive gaseous atmosphere.The actuators are marked with a label of protection against explosion and symbols of the group and category of the device Ex II 2G or Ex I M2; in addition, according to version for surrounding temperature -25°C to + 55°C with marking Ex de IIC T4 or for surrounding temperature -50°C to +55°C with marking Ex de IIB T4, and/or as modification for using in mines of group I, category M2 with marking Ex de I (see chapter Data on actuators).Electro-mechanical control board is replaced with the electronic system DMS2 or DMS2 ED. Both systems scan position of the output shaft and torque of the electric actuator by contact-free magnetic sensors. The sensor of the output shaft position is absolute and does not require any backup power supply in case supply voltage is disconnected during operation of the electric actuator. Both systems can be set and monitored by a computer with controlling programme or manually without a computer.The more simple system DMS2 ED substitutes electromechanical parts and/or provides for controlling the electric actuator by input analog signal as in the version Control.The system DMS2 enables the electric actuator to be used for two-position and three-position regulation or to be connected to the industrial bus bar Profibus.Technical dataMOED EExType number521205212152122521235212452125 20-12563-160160-250250-500320-630630-1100Tripping force [kN]      Adjusting time [s/90°]      Position-changing velocity[min-1]11-4016-12510-8016-10016-6330-100[mm/min]      Working stroke[°]      [ot]2-250 (2-620)2-250 (2-620)2-250 (2-620)2-240 (2-470)2-240 (2-470)2-240 (2-470)[mm]      Supply voltage1x 230 V, 50 Hz      24 V, 50 Hz      1 x 110 V, 50 Hz      3 x 230 / 400 V, 50 Hz✔✔✔✔✔✔ControlTwo position On-Off✔✔✔✔✔✔Three position      Continuous      PROFIBUS✔✔✔✔✔✔Position sensingResistance transmitter (R)      Absolute✔✔✔✔✔✔Current transmitter (I)      Position interrupt✔✔✔✔✔✔Torque-initated interrupt✔✔✔✔✔✔Manual actuation✔✔✔✔✔✔Explosion-proof design✔✔✔✔✔✔Type of enclosureIP 55IP 55IP 55IP 55IP 55IP 55Weight - depending on design (Al/cast iron) and on motor [kg]47-4957-8057-80112-150108-150239-248UsageDesignation of explosion-proof propertiesIt consists of the following symbols:EEx - Electric device complies with the standard EN 50 014 and related standards for various types of protection against explosion.d - Designation of the type of protection against explosion, explosion-proof closure according to EN 50 018.II - Designation of the group of explosion-proof electric device according to ČSN EN 50 014.C - Designation of the sub-group of the group of explosion-proof electric device according to EN 50 014.T4 - Designation of temperature class of explosion-proof electric device of the Group II according to EN 50 014.NomenclatureEnvironment with explosion danger - environment in which an explosive atmosphere can be createdExplosive gaseous atmosphere - a mixture of flammable substances (in the form of gases, vapours or mist) with air under atmospheric conditions in which, after initialization, burning spreads out to non-consumed mixture.Maximum surface temperature - The highest temperature created during operation under the most unfavourable conditions (however within approved limits) on any surface part of the electric device, which could induce ignition of surrounding atmosphere.Closure - All walls, doors, covers, cable bushings, shafts, rods, pull-rods, etc. which contribute to the type of protection against explosion and/or to the level of protection (IP) of the electric device.Explosion-proof closure “d” - Type of protection in which the parts capable of causing ignition of an explosive atmosphere are installed inside the closure; in case of internal explosion this closure should withstand pressure of the explosion and prevent spreading of the explosion into the surrounding atmosphere.Secured design “e” - Type of protection against explosion with additional measures adopted for increased safety against non-permissible temperature increase and formation of sparks or arcs inside and on external parts of the electric device which, under normal operating conditions, does not form sparks or arcs.

Latest Comments for Zpa Pecky MOED EEx Electric Actuator


기타 추천 제품 Zpa Pecky


Zpa Pecky 52326.806F4 Actuator
Zpa Pecky MOK Series Actuator
Zpa Pecky KP MINI Electric Actuator
Zpa Pecky KP MIDI Electric Actuator
Zpa Pecky MOK Series Electric Actuator
Zpa Pecky MOKA Series Electric Actuator
Zpa Pecky MOKED Series Electric Actuator
Zpa Pecky MOKP Ex Sries Electric Actuator
Zpa Pecky MOKPED Ex Series Electric Actuator
Zpa Pecky MONJ Series Electric Actuator
Zpa Pecky MOP Series Electric Actuator
Zpa Pecky MONED Series Electric Actuator
Zpa Pecky MONEDJ Series Electric Actuator
Zpa Pecky MOPED Series Electric Actuator
Zpa Pecky MO EEx Electric Actuator
Zpa Pecky MOED EEx Electric Actuator
Zpa Pecky MOA Electric Actuator
Zpa Pecky MOA Series Electric Actuator