Description for National Lab GUPCNO026.01-NED-System Recirculating Chiller Proficool Novus

For a cooling capacity of 2.6 kW at + 20 ° C cooling medium outlet temperature and + 32 ° C ambient temperatureConsisting of;1. GUPCNO026  ProfiCool Novus PCNO 26 cooling water dry cooler. 1-phase mains connection2. MPCNO6-001-026  Hydraulic design - single circuit system with tank3. MPCNO6-P14-ZA11D-026  Pump P14-ZA11D stainless. Piped ready for use and connected. Mains connection: 230V / 1Ph / 50-60Hz ± 5%.4. ZPCNO6-141-026  Continuous capillary bypass, installed between the front and Return to protect the pump when it is externally closed Cycle.5. ZPCNO6-060-026 Manometer, 0-6 bar, for water pressure display6. MPCNO9-002-026 Refrigeration design, Refrigerant: R407C7. MPCNO9-009-026  Condenser, air-cooled8. MPCNO9-049-026 axial fans, low noise9. MPCNO2-007-026 Electrical design 1 / N / PE AC 230V ± 10% 50-60Hz ± 2%, for single-phase three-wire system. Bi-frequent. Executed with main switch ON / OFF.10. YPCNO2-009-026 Cable for mains connection 2.5 m, 1-phase, without plug.11. YPCNO2-219-026 Electronic controller with digital display, Eliwell EWPLUS 974 EO12. ZPCNO2-001-026 Collective fault message, faults that occur are routed to the terminal in a potential-free manner and can thus be processed further externally. Additional cable entry near the mains connection.13. ZPCNO2-054-026 Remote control, for switching on and off via the consumer. Switches off the entire device.14. MPCNO7-002-026 Design for indoor installation15. YPCNO5-023-STD Leveling feet for ProfiCool Novus, material: plastic (contained in the box).16. MPCNO5-077-026 standard paint in RAL 7035 (light gray)17. YPCNO8-038-026 Labeling in internationally understandable symbols

Latest Comments for National Lab GUPCNO026.01-NED-System Recirculating Chiller Proficool Novus


Other Recommended Products National Lab


National Lab GUPCNO026.01-NED-System Recirculating Chiller Proficool Novus
National Lab PCNO 20.03-NED Recirculating Chillers
National Lab PCGE 11 bis 1.1 kW Cooling water recooler
National Lab PCGE 21 bis 2.0 kW Cooling water recooler
National Lab PCGE 25 bis 2.5 kW Cooling water recooler
National Lab PCGE 28 bis 3.5 kW Cooling water recooler
National Lab PCNO 11 bis 1.1 kW Cooling water recooler
National Lab PCNO 21 bis 2.1 kW Cooling water recooler
National Lab PCNO 26 bis 2.6 kW Cooling water recooler
National Lab PCNO 39 bis 3.9 kW Cooling water recooler
National Lab PCPR 009 bis 0.9 kW Cooling water recooler
National Lab PCPR 013 bis 1.3 kW Cooling water recooler
National Lab PCPR 020 bis 2.0 kW Cooling water recooler
National Lab PCMO 35 bis 3.7 kW Cooling water recooler
National Lab PCMO 45 bis 4.7 kW Cooling water recooler
National Lab PCMO 60 bis 6.2 kW Cooling water recooler
National Lab PCFi04 bis 0.4 kW Cooling water recooler
National Lab PCFi06 bis 0.6 kW Cooling water recooler