Gestra LRGS 15-1

Gestra

Номер продукта: LRGS 15-1
Продюсер: Gestra
Confirmed Rating: ☆☆☆☆ ☆☆ (2.4)
Rating Count: 5543

Вы можете заполнить форму онлайн-предложения или связаться со службой поддержки в режиме реального времени для получения информации. Gestra бренд, LRGS 15-1 продукт. Мы свяжемся с вами как можно скорее.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Gestra LRGS 15-1

Description for Gestra LRGS 15-1

Technical Data Service pressure PN25: 25 barg at 224 °C Mechanical connection Screwed ¾Inch, ISO 228-1 Screwed ¾Inch NPT (optional) Materials Screw-in electrode body: 1.4571, X6CrNiMoTi17-12-2 or 1.4404, A 479 316 L (for NPT thread) Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 Electrode rod insulation: PTFE Terminal box: Polycarbonate Measuring length & length of installation 200, 300, 400, 500, 600, 800, 1000 mm Input 1 Input for resistance thermometer, e. g. TRG 5-53, measuring insert Pt 100 Measuring range 100 to 10000 µS/cm at 25 °C or 50 to 5000 ppm at 25 °C Setpoint Adjustable between 100 and 10000 µS/cm or 50 to 5000 ppm MAX limit Adjustable between 100 and 10000 µS/cm or 50 to 5000 ppm Switching hysteresis Controller output: –10 % of the adjusted setpoint MAX limit: –3 % of the adjusted MAX limit Temperature coefficient Tk (if a resistance thermometer Pt 100 is connected) 1.6 – 3.0 % per °C, adjustable in steps of 0.1 Supply voltages 230 V, +10 / –15 %, 50-60 Hz 115 V, +10 / –15 %, 50-60 Hz (optional) Power consumption 5 VA Fuse External slow-blow fuse 63 mA at 230 V External slow-blow fuse 125 mA at 115 V Output 3 Volt-free relay contacts 5 A 230 V AC / 30 V DC cos φ = 1 (IEC 61810) Provide contactor with inference suppressor (RC combination). Contact material: AgNi 0.15 Indicators and adjustors 1 Four-digit, seven-segment indicator, red, for showing the actual value (X) / setpoint (W) and status & malfunction messages 2 Amber LEDs for indicating the actual value (X) / setpoint (W) 1 Red LED for indicating the MAX limit 2 Green LEDs for indicating “Valve OPEN / CLOSED” 4 Pushbuttons for parameter settings Cable entry / Electrical connection Cable glands with integrated cable clamp, 3 x M 16 x 1.5 1 Four-pole screw-type terminal strip for mains connection 1 Three-pole screw-type terminal strip for connecting the continuous blowdown valve 1 Three-pole screw-type terminal strip for MAX limit The terminal strips can be detached; conductor size 1.5 mm2 4 Terminal lugs for connecting the resistance thermometer Protection IP 65 to DIN EN 60529 Protection class 2 (protective insulation) Weight Approx. 1.5 kg Ambient temperature when system is switched on: 0 ° ... 70 °C, during operation: -10 ... 70 °C Transport temperature –20 ... +80 °C (< 100 hours), defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Storage temperature –20 ... +70 °C, defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Relative humidity max. 95%, no moisture condensation Site altitude max. 2000 m

Latest Comments for Gestra LRGS 15-1


Другие рекомендуемые продукты Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART