Gestra NRG16-50 PN40 level electrode

Gestra

Номер продукта: NRG16-50 PN40
Продюсер: Gestra
Confirmed Rating: ☆☆☆☆ ☆☆ (2.3)
Rating Count: 3304

Вы можете заполнить форму онлайн-предложения или связаться со службой поддержки в режиме реального времени для получения информации. Gestra бренд, NRG16-50 PN40 продукт. Мы свяжемся с вами как можно скорее.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Gestra NRG16-50 PN40 level electrode

Description for Gestra NRG16-50 PN40 level electrode

Description The level electrodes NRG 1...-51 are used in conjunction with level switch NRS 1-51 as high level alarm for steam boiler plants and (pressurized) hot water installations. A high level alarm prevents the water level from exceeding the preset max. water level (HW) and for this purpose switches off e. g. the feedwater supplyTechnical data Service pressure NRG 16-51, PN 40, 32 bar at 238 °C NRG 17-51, PN 63, 46 bar at 260 °C NRG 19-51, PN 160, 100 bar at 311 °C NRG 111-51, PN 320, 183 bar at 357 °C Mechanial connection Screwed G¾ A, ISO 228 (NRG 16-51, NRG 17-51, NRG 19-51) Screwed G1 A, ISO 228 (NRG 111-51) Materials Screw-in body: 1.4571 X6 CrNiMoTi 17-12-2 (NRG 16-51, NRG 17-51, NRG 19-51) Screw-in body: 1.4529 X1NiCrMoCuN25-20-7 (NRG 111-51) Measuring electrode: 1.4571 X6 CrNiMoTi 17-12-2 (NRG 16-51, NRG 17-51, NRG 19-51) Measuring electrode: 1.4122 X39CrMo17-1 (NRG 111-51) Electrode tip: 1.4401 X5 CrNiMo 17-12-2 Electrode insulation: PEEK (NRG 16-51, NRG 17-51, NRG 19-51) Electrode insulation: special ceramic (NRG 111-51) NRG 1...-51: Four-pole connector: polyamide (PA) NRG 1...-51F: Terminal box 3.2161 G AlSi8Cu3 Lengths available 500 mm, 1000 mm, 1500 mm pH value Max. admissible: 10 (only NRG 111-51) Electrical conductivity Max. admissible: 100 μS/cm at 25 °C (only NRG 111-51) Electrical connection NRG 1-51: Four-pole connector, cable gland M19 (PG 11) NRG 1...-51F: Aluminium terminal box, cable gland M20 Protection IP 65 to DIN EN 60529 Admissible ambient temperature Max. 70°C Weight Approx. 1.2 kg (without extension) (NRG 16-51, NRG 17-51, NRG 19-51) Approx. 2.1 kg (without extension) (NRG 16-51F, NRG 17-51F, NRG 19-51F) Approx. 1.8 kg (without extension) (NRG 111-51) Approx. 2.7 kg (without extension) (NRG 111-51F)

Latest Comments for Gestra NRG16-50 PN40 level electrode


Другие рекомендуемые продукты Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART