Gestra NRG17-41.1

Gestra

Номер продукта: NRG17-41.1
Продюсер: Gestra
Confirmed Rating: ☆☆☆☆☆ (3.5)
Rating Count: 14202

Вы можете заполнить форму онлайн-предложения или связаться со службой поддержки в режиме реального времени для получения информации. Gestra бренд, NRG17-41.1 продукт. Мы свяжемся с вами как можно скорее.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Gestra NRG17-41.1

Description for Gestra NRG17-41.1

System Description The level electrode operation is based on the conductive measuring principle. The NRG 1...-41.1 is designed for signalling the max. liquid level in electrically conductive liquids. n One liquid level with one switchpoint The NRG 1...-41.1 is to be used in conjunction with the multi-purposed control equipment NRS 1-40.1. The level data are transferred from the electrode NRG 1...-41.1 to the control unit via a CAN bus using the CANopen protocol. Function The conductivity of the liquid is used to signal the liquid level. Some liquids are conductive, which means that they allow an electric current to flow through them. For the safe functioning of this device a minimum conductivity of the liquid to be measured is required. The conductivity measurement method can detect two conditions: electrode rod submerged or exposed, meaning switchpoint reached (or exceeded) or not yet reached. Before installation, the length of the electrode rod must be cut to the required switching level, e. g. for “Pump off” or “Control valve closed” or, in case of economiser and air heaters that are installed close to the steam-generating unit and exposed to a risk, “Firing/Burner off”. An additional electrode fully integrated in the system automatically monitors the electrical resistance path between earth and measuring electrode. As soon as the actual value falls below the admissible resistance value the protection circuit is interrupted and cuts off the pump or heat supply to the boiler. At regular intervals the level electrode NRG 1...-41.1 sends a data telegram to the switching controller NRS 1-40.1. The data are transferred via a CAN bus to DIN ISO 11898 using the CANopen protocol.

Latest Comments for Gestra NRG17-41.1


Другие рекомендуемые продукты Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART