SICK 1049053 type: WTB9-3N2461 Small photoelectric sensor

Access stock, delivery and price for SICK 1049053 type: WTB9-3N2461 Small photoelectric sensor with SICK. SICK, 1049053, SICK 1049053, type:, SICK type:, 1049053 type:, SICK 1049053 type:
Product number WTB9-3N2461
Producer SICK

Description: WTB9-3N2461 ( SICK )

SICK 1049053 type: WTB9-3N2461 Small photoelectric sensor



Product Name: SICK 1049053 type: WTB9-3N2461 Small photoelectric sensor
Product Brand: SICK
Product Code: WTB9-3N2461
Product Artikel: SICK 1049053 type: WTB9-3N2461 Small photoelectric sensor
FEATURES Sensor/ detection principle Photoelectric proximity sensor, Background suppression Dimensions (W x H x D) 12.2 mm x 52.2 mm x 23.6 mm Housing design (light emission) Rectangular Mounting hole M3 Sensing range max. 20 mm ... 350 mm  1) Sensing range 20 mm ... 200 mm  2) Type of light Visible red light Light source PinPoint LED  3) Light spot size (distance) Ø 4.5 mm (75 mm) Wave length 650 nm Adjustment Potentiometer, 5 turns 1)  Object with 90 % reflectance (referred to standard white, DIN 5033). 2)  Object with 6 % reflectance (referred to standard white, DIN 5033). 3)  Average service life: 100,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple pp   2) Power consumption 30 mA  3) Switching output NPN  4) Output function Complementary Switching mode Light/dark switching  4) Output current I max. ≤ 100 mA  5) Response time 6) Switching frequency 1,500 Hz  7) Connection type Male connector M12, 4-pin Circuit protection A  8) B  9) C  10) Protection class III Weight 13 g Housing material Plastic, VISTAL® Optics material Plastic, PMMA Enclosure rating IP66 IP67 IP69K Ambient operating temperature –40 °C ... +60 °C Ambient storage temperature –40 °C ... +75 °C UL File No. NRKH.E181493 1)  Limit values when operated in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  Without load. 4)  Q = light switching. 5)  At and above Tu 50 °C, a max. load current of Imax. = 50 mA is permitted. 6)  Signal transit time with resistive load. 7)  With light/dark ratio 1:1. 8)  A = V S  connections reverse-polarity protected. 9)  B = inputs and output reverse-polarity protected. 10)  C = interference suppression. CLASSIFICATIONS ECl@ss 5.0 27270904 ECl@ss 5.1.4 27270904 ECl@ss 6.0 27270904 ECl@ss 6.2 27270904 ECl@ss 7.0 27270904 ECl@ss 8.0 27270904 ECl@ss 8.1 27270904 ECl@ss 9.0 27270904 ECl@ss 10.0 27270904 ECl@ss 11.0 27270904 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 UNSPSC 16.0901 39121528

Other Recommended Products SICK