Ayvaz Ex-Proof Protection Hose

Ayvaz markalı Ayvaz Ex-Proof Protection Hose ürününün fiyat ve detaylarını inceleyerek hemen teklif alabilirsiniz! Ayvaz, , Ayvaz , Ex-Proof, Ayvaz Ex-Proof, Ex-Proof, Ayvaz Ex-Proof, , Ayvaz , , Ayvaz , Ex-Proof
Hemen teklif alabilirsiniz: info@industrialmaterialcenter.com
Ürün No Ex-Proof
Üretici Ayvaz

Description: Ex-Proof ( Ayvaz )

Ayvaz Ex-Proof Protection Hose



Product Name: Ayvaz Ex-Proof Protection Hose
Product Brand: Ayvaz
Product Code: Ex-Proof
Product Artikel: Ayvaz Ex-Proof Protection Hose
The petroleum usually evaporates in normal temperature, and is dangerous enough to be ignited or explode by a tiny electric spark including open-close operation of a switch or a static spark according to its evaporative condition or temperature. Also, gases including LPG and LNG could cause the exactly same dangerous condition when leaked and mixed with the air. Where this phenomenon happens is called, “Hazardous area” and any electric equipment used there is required to be “Explosion-proof”. Explosion proof is a term used to describe electrical and non-electrical fixtures that are designed and constructed to both withstand explosions and prevent explosions from occurring. Explosion Proof Class Ratings Class I Environments containing flammable gases or vapors. Class II Environments containing combustible dusts. Class III Environments containing easily ignitible fibers or flyings Flexible Metal Hose as Explosion Proof Apparatus According to NFPA (National Fire Protection Association) “Apparatus enclosed in a case that is capable of withstanding an explosion of a specific gas or vapor that may occur within it and of preventing the ignition of a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and that operates at such an external temperature that a surrounding flammable atmosphere will not be ignited thereby.” Ayvaz flexible metal hoses are widely used as a protective cover for electric cables which are potentially subjected to produce sparks or arcs. Main purpose of the hoses is to prevent.           Hazardous areas that needs explosion-proof electric apparatus. 1. Petro-based product factory 2. Petroleum refinery plant 3. Tunnel digging site (Methane gas) 4. LP gas filling-up station 5. Crude oil base, LNG base 6. Petro/natural gas stockpiling area 7. Thermal power plant 8. Dyeing Factory (Paint) Service Life and Installation Service life of the hose is mainly dependent on the working conditions, application angle and temperature, correct installation is also very influential on the service life. For optimum service life of the hose assembly following features should be provided; The hose line should be installed without exposed to twisting. • No torsion stress must occur neither during the assembly, nor the operating. Otherwise, the service life of the hose falls. • Both ends of the hose and the movement must be on the same plate. • Only one end of the hose must be tightened first to be assured that no twisting on the hose assembly occurs. Afterwards, the hose must complete its movement for couple time while it is in neutral position under no torsions. • Finally the other end of the hose must be connected.

İlginizi Çekebilecek Ürünler Ayvaz