industrialmaterialcenter.com

Hawe HSV 61 R2-G24 Directional Seated Valve Combination

Hawe

Ürün No: HSV 61 R2-G24 Directional Seated Valve Combination
Üretici: Hawe
Confirmed Rating: ☆☆☆☆☆☆ (4.8)
Rating Count: 7947

Hawe markalı, HSV 61 R2-G24 Directional Seated Valve Combination koduna sahip Hawe HSV 61 R2-G24 Directional Seated Valve Combination isimli ürün hakkında detaylı bilgi almak için lütfen canlı destek ekibimiz ile hemen iletişime geçin ya da bir online teklif formu doldurun. Size en kısa sürede dönüş yapacağız.
PLEASE MAIL TO: info@industrialmaterialcenter.com

Datasheets for Hawe HSV 61 R2-G24 Directional Seated Valve Combination

Description for Hawe HSV 61 R2-G24 Directional Seated Valve Combination

Product DescriptionPmax: 400 barQmax: 60 lpmSeries: HSVSize: 6Flow Pattern: R2 (with throttle valve)Function: 2/2 wayVoltage: 24V DCProduct InformationLifting-lowering valves are a combination of directional valves and metering valves.The valve block type HSV provides the function of a 2/2-way directional seated valve with electrical actuation for lowering the load. Adjustable throttle valves or flow control valves independent of the load control the lowering speed. An integrated pressure-limiting valve limits the permissible load.The lifting/lowering valve type HSV is used to control lifting equipment with single-acting cylinders.This valve combination type HSV is preferably used for controlling lifting equipment with one or two single acting hydraulic cylinders. The valve consists of:Solenoid actuated 2/2-way directional seated valve for lowering the lifted loadAdjustable throttle valve (optional) for limiting the drop rateThe 2-way flow control valve, available as option for valves type HSV 23-R6, ensure a largely load independent drop ratePressure limiting valve for the limitation of the permissible load (max. operation pressure). Factory set to 220 bar, adjustable up to 400 bar.Check valve prevents load pressure from acting on the switched off pump, when the load is lifted and prevents e.g. reverse rotation of the pump. The location of the check valve in relation to the pressure limiting valve depends on the application. Version R2 and R4 (S2 and S4) prevents uncontrolled lowering of the load in case the pressure limiting valve is floating (load pressure in the range of the set pressure).

Latest Comments for Hawe HSV 61 R2-G24 Directional Seated Valve Combination


İlginizi Çekebilecek Ürünler Hawe


Hawe 7500-0096-00.HW BASE PER VALVOLA
Hawe DG35 PRESSOSTATO HAWE
Hawe DG35Y8 Pressure
Hawe DS6010-2 KIT GUARNIZIONI
Hawe EV1M3-12/24 SCHEDA ELETTRONICA
Hawe GR2-2 ELETTROV.CON BOBINA 24VDC
Hawe HRP-2 Releasable check valve
Hawe LP80-12 Air Driven Hydraulic Pump
Hawe PDM4PH-G24 REGOLATORE DI PRESSIONE PROPORZIONALE
Hawe PE12 ELEMENTO POMPA
Hawe R3,6A POMPA A PISTONI
Hawe R5,3 POMPA A PISTONI
Hawe R6,0A POMPA A PISTONI
Hawe RC1 RITEGNO A CARTUCCIA 1/4
Hawe RH3V VALVOLA RIT.PILOT.
Hawe TQ43-A4 DIVISORE DI FLUSSO
Hawe VP1Z-1/4-G24 VALVOLA A SEDE 24VDC
Hawe 6900 4920-04 Pressure Switch