SICK 6036922 type: UM30-212118 Ultrasonic sensor
SICK
Ürün No: UM30-212118
Üretici: SICK
Confirmed Rating:
☆☆☆☆
☆☆ (2.4)
Rating Count: 8282
SICK markalı, UM30-212118 koduna sahip SICK 6036922 type: UM30-212118 Ultrasonic sensor isimli ürün hakkında detaylı bilgi almak için lütfen canlı destek ekibimiz ile hemen iletişime geçin ya da bir online teklif formu doldurun. Size en kısa sürede dönüş yapacağız.
PLEASE MAIL TO: info@industrialmaterialcenter.com
Datasheets for SICK 6036922 type: UM30-212118 Ultrasonic sensor
Description for SICK 6036922 type: UM30-212118 Ultrasonic sensor
MECHANICS/ELECTRONICSSupply voltage VsDC 9 V ... 30 V 1) 2)Power consumption≤ 2.4 W 3)Initialization time< 300 msDesignCylindricalHousing materialNickel-plated brass, PBTDisplay: TPUUltrasonic transducer: polyurethane foam, glass epoxy resinConnection typeMale connector, M12, 5-pinIndicationLED display, 2 x LEDWeight150 gSending axisStraightEnclosure ratingIP65 / IP67Protection classIII1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.2) When using the analog voltage output.3) Without load.PERFORMANCEOperating range, limiting range65 mm ... 350 mm, 600 mmTargetNatural objectsResolution≥ 0.18 mmRepeatability± 0.15 % 1)Accuracy± 1 % 1) 2)Temperature compensation✔Response time64 ms 3)Switching frequency12 HzOutput time16 msUltrasonic frequency (typical)400 kHzDetection area (typical)See diagramsAdditional functionAdjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, reset to factory default1) Referring to current measurement value.2) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.3) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.INTERFACESDigital outputNumber1 1)TypePNPMaximum output current IA≤ 200 mAAnalog outputNumber1TypePower output / voltage outputFunctionAutomatic selection of analog current or voltage output dependent on loadCurrent4 mA ... 20 mA, ≤ 500 Ω 2)Voltage0 V ... 10 V, ≥ 100,000 ΩResolution12 bitMultifunctional input (MF)1 x MFHysteresis5 mm1) PNP: HIGH = VS - (< 2 V) / LOW = 0 V.2) For 4 mA ... 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.AMBIENT DATAAmbient temperature operation–25 °C ... +70 °CAmbient storage temperature–40 °C ... +85 °CCLASSIFICATIONSECl@ss 5.027270804ECl@ss 5.1.427270804ECl@ss 6.027270804ECl@ss 6.227270804ECl@ss 7.027270804ECl@ss 8.027270804ECl@ss 8.127270804ECl@ss 9.027270804ETIM 5.0EC001846ETIM 6.0EC001846UNSPSC 16.090141111960
Latest Comments for SICK 6036922 type: UM30-212118 Ultrasonic sensor
İlginizi Çekebilecek Ürünler SICK