Fisher OSE Slam-Shut Valve

使用产品代码 OSE 访问产品#Fisher 的库存,交货和价格信息。 Fisher, OSE, Fisher OSE, , Fisher , OSE , Fisher OSE , Slam-Shut, Fisher Slam-Shut, OSE Slam-Shut, Fisher OSE Slam-Shut
产品编号 OSE
生产厂家 Fisher

Description: OSE ( Fisher )

Fisher OSE Slam-Shut Valve



Product Name: Fisher OSE Slam-Shut Valve
Product Brand: Fisher
Product Code: OSE
Product Artikel: Fisher OSE Slam-Shut Valve
Fisher™ Type OSE Slam-Shut Valve Type OSE slam-shut valve is used to rapidly cut the gas flow during an overpressure or underpressure event. It is ideal for gas applications requiring positive shutoff protection, tight accuracy, fa Features Overpressure and Underpressure Protection High Shock and Vibration Resistance - Type OSE incorporates a two-stage tripping mechanism that significantly reduces nuisance tripping caused by vibrations or inlet pressure variations commonly experienced by other shut-off valves. High Accuracy - Maintains up to ±1% accuracy regardless of inlet pressure, flowrate and the size of the slam-shut. Easy In-Line Maintenance - Top entry design reduces maintenance time and manpower requirements; parts can be inspected and replaced without removing the body from the line. Water Tight - Type OSE is water tight to 10 ft / 3.0 m. Positive Shutoff - After closing, the slam-shut valve stays closed until the system is shut down and the valve is manually reset. An O-ring on the valve plug seal provides tight shutoff. Remote Alarm Capability - A limit switch is available that detects when the Type OSE slam-shut valve is tripped. Specifications Body Sizes and End Connection Styles WCC Steel: 1 and 2 NPT; NPS 1, 2, 3, 4 and 6 / DN 25, 50, 80, 100 and 150; CL150 RF, CL300 RF or CL600 RF LCC Steel: NPS 8 and 10 / DN 200 and 250; CL150 RF, CL300 RF or CL600 RF Cast Iron: 1 and 2 NPT; NPS 1, 2, 3, 4 and 6 / DN 25, 50, 80, 100 and 150; CL125 FF Pressure Ratings Maximum Inlet Pressure: 101 bar / 1470 psig or max. body rating Maximum Set Pressure: 101 bar / 1470 psig or max. body rating Minimum Set Pressure: 10 mbar / 4.02-inches w.c. Maximum Shutoff Pressure Differential 100 bar / 1450 psig Manometric Sensing Device Specifications Spring Ranges: 10 mbar to 72,9 bar / 4.02-inches w.c. to 1058 psig Maximum Sensing Inlet Pressure: 72,9 bar / 1058 psig Setpoint Tolerance: 0,004 bar / 0.058 psig to 12,0 bar / 174 psig Maximum Difference Between Overpressure and Underpressure: 33,0 bar / 479 psig Temperature Capabilities -30° to 82°C / -22° to 180°F Pressure Sensing Connections 1/4 NPT Options Explosion-proof switch Non-explosion-proof limit switch Solenoid Additional manometric device for extra pressure sensing st speed of response, and high shock and vibration resistance. The top entry design makes in-line maintenance easy, saving time and manpower requirements.

其他推荐产品 Fisher