Grünewald Small-Ex Viscoflow Oil Flow

使用产品代码 Small-Ex Viscoflow Oil Flow 访问产品#Grünewald 的库存,交货和价格信息。 Grünewald, Small-Ex, Grünewald Small-Ex, Viscoflow, Grünewald Viscoflow, Small-Ex Viscoflow
产品编号 Small-Ex Viscoflow Oil Flow
生产厂家 Grünewald

Description: Small-Ex Viscoflow Oil Flow ( Grünewald )

Grünewald Small-Ex Viscoflow Oil Flow



Product Name: Grünewald Small-Ex Viscoflow Oil Flow
Product Brand: Grünewald
Product Code: Small-Ex Viscoflow Oil Flow
Product Artikel: Grünewald Small-Ex Viscoflow Oil Flow
SMALL-Ex® Measuring Instruments are intrinsically safe volume flow measuring instruments for pure oil. In the volume flow measuring instrument is an arrangement of gears, whose revolutions are counted by a impulse sensor. They can be  equipped with integrated pressure and/or temperature measuring sensors.  The volume flow will transmitted as analogous signal with a signal range of 5-15 Hz,  0/4-20 mA, *-** V (max. 10 V DC; at a power supply of min. 7.5 V DC) or CAN-Bus. Also possible is a „pulse output“, up to max. 1kHz at which the volume can be counted because a defined amount of oil flows through the device per pulse.The volume flow measuring instrument for oil can be used as an instantaneous display of liters per minute or impluse output as „counting“. The oil is passed through gear-wheels so per count, a defined amount of oil flows. Thus, the instrument is independent of viscosities or temperetures. This value will be transmitted via an arbitrary signal and also optionally displayed in the illuminated display on site.This measuring instrument can be used e.g. in hydraulic systems up to 400 bar for measurement of pump performance or (the impulse version) for displacement measurement of hydraulic cylinders. Marking:Certifications:       Env. Tempemperature:  Housing Material: Gauge Accuracy: Medium Illuminated Display: Display: Output Signal: Nennspannung:  I Ex ia I MaEx ia I MaPO Ex ia I Ma XBVS 06 ATEX E005 XIECEx BVS 09.0056XIECEx TSA 13.0023XMSHA 18-ISA 150004-0TC RU C-DE.M?62.B.03774MA J2012330, J2012329 -50 to +100 °C bei Gruppe I-50 to +80 °C bei Gruppe II Stainless Steel, Cast Iron(depending on type) +/- 0,5% from end-value (higher accuracy on request) pure oil, fuel optional l/min; l/sec; gpm (other units on reauest) 5 - 15Hz0/4 - 20mA * - **V (max. 10 V DC, at min. 7,5V power supply) pulse output up to 1 kHzCAN-Bus 12V DC (7,5 – 14,0 V DC) 3-wiring technology16V DC (9,6 – 16,1 V DC) 3-wiring technology24V DC (14 – 26,6 V DC) 2-wiring technology