Hirschmann M-Sfp-Sx/Lc 943014-001 Multimode Module

使用产品代码 M-Sfp-Sx/Lc 943014-001 Multimode Module 访问产品#Hirschmann 的库存,交货和价格信息。 Hirschmann, M-Sfp-Sx/Lc, Hirschmann M-Sfp-Sx/Lc, 943014-001, Hirschmann 943014-001
产品编号 M-Sfp-Sx/Lc 943014-001 Multimode Module
生产厂家 Hirschmann

Description: M-Sfp-Sx/Lc 943014-001 Multimode Module ( Hirschmann )

Hirschmann M-Sfp-Sx/Lc 943014-001 Multimode Module



Product Name: Hirschmann M-Sfp-Sx/Lc 943014-001 Multimode Module
Product Brand: Hirschmann
Product Code: M-Sfp-Sx/Lc 943014-001 Multimode Module
Product Artikel: Hirschmann M-Sfp-Sx/Lc 943014-001 Multimode Module
The Hirschmann M-SFP-SX/LC (P/N: 943014-001) is an SFP fiber optic Gigabit Ethernet transceiver. Multimode fiber with LC style connector. Made for use with Hirschmann MICE media modules, MM4-4TX/SFP and MM4-2TX/SFP, OpenRail RS30-Switches and MACH 4000 Ethernet switches. Specifications Network Size - Length of Cable Multimode fiber (MM) 50/125 µm: 0 - 550 m 0 - 7,5 dB link budget at 850 nm A = 3 dB/km, 3 dB reserve, B = 400 MHz x km Multimode fiber (MM) 62.5/125 µm: 0 - 275 m 0 - 7,5 dB link budget at 850 nm A = 3,2 dB/km, 3 dB reserve, B = 200 MHz x km Power Requirements Operating voltage: Power supply via the switch Power Consumption: 1 W Service Diagnostics: Optical input- and output power, transceiver temperature Ambient Conditions Operating temperature: 0 C to 60 C Storage temperature: -40 C to 85 C Relative humidity: 10% to 95% Mechanical Construction Dimensions: 20 mm x 18 mm x 50 mm Mounting: SFP Slot Weight: 40 g Protection Class: IP 20 Mechanical Stability IEC 60068-2-27 shock: 15 g, 11 ms duration 18 shocks IEC 60068-2-6 vibration: 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. EMC Interference Immunity EN 61000-4-2 electrostatic discharge (ESD): 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field: 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst): 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage: power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 conducted immunity: 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC Emitted Immunity FCC CFR47 Part 15: FCC CFR47 Part 15 Class A EN 55022: EN 55022 Class A Approvals Safety of information technology equipment: cUL 60950-1 Shipbuilding: Germanischer Lloyd, ABS, BV, DNV, LR, KR, RINA Accessories To order separately: SFP module

其他推荐产品 Hirschmann