Description: DRVP10 ( Hydac
)
Hydac DRVP10 Needle Valves
Product Name: Hydac DRVP10 Needle Valves
Product Brand: Hydac
Product Code: DRVP10
Product Artikel: Art.Nr. 3725180
Needle Valves
with and without reverse flow check direct-acting Manifold Mounted – 350 bar DVP-/ DRVP- 06 to 40 ·
For regulating the speed of loads ·
For fine adjustment and shut-off of the flow ·
For system-related damping in hydraulic
circuits ·
To release pressure from accumulator systems ·
As an emergency drain for lowering a load ·
Spindle patented secured before complete
loosening ·
An Allen set-screw locks the setting of the
knob ·
Choice of nine sizes ensures best possible
adaptability to the system ·
Optional nickel-plated version available (up
to size 12)
Operating pressure:
max. 350 bar
Nominal flow:
DVP, DRVP-06 max.
20 l/min
DVP, DRVP-08 max.
50 l/min
DVP, DRVP-10 max.
60 l/min
DVP, DRVP-12 max.
90 l/min
DVP, DRVP-16 max.
180 l/min
DVP, DRVP-20 max.
300 l/min
DVP, DRVP-25 max.
300 l/min
DVP, DRVP-30 max.
300 l/min
DRVP-40 max. 300
l/min
Cracking pressure
(on DRVP):
0.5 bar
Media operating
temperature range:
min. -20 °C to max.
+80 °C
Ambient temperature
range:
min. -20 °C to max.
+80 °C
Operating fluid:
Hydraulic oil to
DIN 51524 Part 1, 2 and 3
Viscosity range:
min. 2.8 mm²/s to
max. 800 mm²/s
Filtration:
Class 21/19/16
according to ISO 4406 or cleaner
MTTF d :
150 - 1200 years,
according to DIN EN ISO 13849-1
Installation:
No orientation
restrictions, preferably horizontal
Materials:
Valve body: steel
Piston: hardened and ground steel Seals: FKM (standard) Back-up rings: PTFE
Weight:
DVP 06 = 0.2 kg
DRVP 06 = 0.3 kg DVP 08 = 0.4 kg DRVP 10 = 0.8 kg
DVP 10 = 0.6 kg
DRVP 12 = 1.1 kg DVP 12 = 1.0 kg DRVP 16 = 2.5 kg
DVP 16 = 1.7 kg
DRVP 25 = 6.7 kg DVP 20 = 3.6 kg DRVP 30 = 3.9 kg
DVP 25 = 5.5 kg DRVP
40 = 17.5 kg DVP 30 = 7.5 kg
The DVP is a manifold mounted flow control valve which
controls the flow rate by adjusting the cross-section. The flow rate is
therefore dependent on the pressure differential and viscosity. Starting with the throttle spindle in the fully closed
position, the flow rate increases in accordance with the appropriate curve as
the control knob is turned. The flow is controlled in both directions. The
scale and coloured rings on the top of the control knob enable accurate repeat
setting.
The DRVP is a manifold mounted flow control valve which
allows the same fine flow adjustment, but in one direction only. Unrestricted
flow in the reverse direction is via the built-in check valve (cracking
pressure 0.5 bar).