Janitza UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer

使用产品代码 UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer 访问产品#Janitza 的库存,交货和价格信息。 Janitza UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer, Janitza
产品编号 UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer
生产厂家 Janitza

Description: UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer ( Janitza )

Janitza UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer



Product Name: Janitza UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer
Product Brand: Janitza
Product Code: UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer
Product Artikel: Janitza UMG 512-PRO 95 ... 240 V AC, 80 ... 300 V DC Power Quality Analyzer
Power quality Harmonics analysis up to the 63rd harmonic, even / odd (U, I, P, Q) Interharmonics (U, I) Distortion factor THD-U / THD-I / TDD Measurement of positive, negative and zero sequence component Unbalance Direction of rotation field Voltage crest factor Flicker measurement in accordance with DIN EN 61000-4-15 Logging and storage of transients (> 39 µs) Short-term interruptions (> 10 ms) Monitoring start-up processes High quality measurement Constant true RMS measurement Measurement process in accordance with IEC 61000-4-30 Certified accuracy of measurement according to class A Continuous sampling of the voltage and current measurement inputs at 25,6 kHz 512 measurement points per period Recording of over 2,000 measured values per measurement cycle Accuracy of active energy measurement: Class 0.2S Fast measurement even enables the logging of rapid transients from 39 µs Logging of currents and voltages (15 – 440 Hz) User-friendly, colour graphical display with intuitive user guidance High resolution colour graphical display 320 x 240, 256 colours, 6 buttons User-friendly, self-explanatory and intuitive operation Backlight for optimum reading, even in darker environments Illustration of measured values in numeric form, as a bar graph or line graph Clear and informative representation of online graphs and power quality events Multilingual: German, English, Russian, Spanish, Chinese, French, Turkish ... RCM (Residual Current Monitoring) Continuous monitoring of residual currents (Residual Current Monitor, RCM) Alarming in case a preset threshold fault current reached Near-realtime reactions for triggering countermeasures Permanent RCM measurement for systems in permanent operation without the opportunity to switch off Ideal for the central earthing point in TN-S systems BACnet protocol for building communication Optimal interoperability between devices from various manufacturers Predefined BIBBs (BACnet Interoperability Building Block) BACnet is optionally available with UMG 512-PRO UMG 512-PRO supports the device type B-SA with the BIBBs DS-RP-B and DS-WP-B Furthermore, the BIBBs DS-COV-B and DM-UTC-B are also supported Comprehensive communication and connection possibilities 4 voltage and 6 current measurement inputs 2 digital inputs, e.g. as data logger for S0 meter 2 digital outputs for alarm message or e.g. for connection to a BMS or PLC Free name assignment for the digital IOs, e.g. if used as data logger Modbus Profibus Ethernet (TCP/IP) Digital IOs BACnet (optional) Configurable Firewall Modern communications architecture via Ethernet Simple integration in an Ethernet network Reliable and cost-optimised establishment of communication Ideal for Master-Slave structures High flexibility due to the use of open standards Integration in PLC systems and BMS through additional interfaces Various IP protocols: SNMP, ICMP (Ping), NTP, FTP … Up to 4 ports simultaneous Programming / PLC functionality Further processing of the measurement data in the measuring device (local intelligence) Monitoring and alarm functions simple to program Sustainable functional expansions far beyond pure measurement Comprehensive programming options with Jasic ®  source code programming Graphical programming Complete APPs from the Janitza library Large measurement data memory 256 MB data memory Memory range up to 2 years (configuration-dependent) Individually configurable recordings Recording averaging times can be freely selected PQ recordings template preconfigured for conventional standards (e.g. EN 50160) User-defined memory segmenting possible Powerful alarm management Information available immediately by email Inform maintenance personnel via the powerful device homepage Via digital outputs, Modbus addresses, GridVis ®  software Programming via Jasic ®  or graphical programming Further alarm management functions via GridVis ® -Service alarm management Peak load representation and peak load management Illustration of the 3 highest monthly power peaks on the LCD display (P, Q, S) Rolling bar chart representation of the peak power values over 3 years on the LCD display (P, Q, S) Plain text representation on the LCD display (P)

其他推荐产品 Janitza